| 8655.1 |
1.5 Mechanical Lock |
24 Ga. 16" wide over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -123.5PSF @ 6” o.c. clip spacing.
-59.75PSF @ 24” o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL8655_R6_II_RSSr FL 8655.1 REPORT AND INSTALL DETAILS 2023.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8655_R6_AE_RSSr FL 8655.1 REPORT AND INSTALL DETAILS 2023.pdf Created by Independent Third Party: Yes |
|
|
| 8655.2 |
1.5 Nail Strip |
24 Ga. 15 1/2" wide over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -78.5 PSF @ 11" o.c. fastener spacing in slot. -116.0 psf @ 6 1/2" o.c. fastener spacing in slot and 12" o.c. fastener spacing in Pan (See Details). Install per manufacturers details. For use in HVHZ Zones.
|
Installation Instructions FL8655_R6_II_SSr FL 8655.2 REPORT AND INSTALL DETAILS 2023.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8655_R6_AE_SSr FL 8655.2 REPORT AND INSTALL DETAILS 2023.pdf Created by Independent Third Party: Yes |
|
|
| 8655.3 |
1.5 Snap Lock |
24 Ga. 16" wide over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -108.5PSF @ 12” o.c.clip spacing. -116.0PSF @ 6” o.c. clip spacing. -86.0PSF @ 24” o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL8655_R6_II_SSr FL 8655.3 REPORT AND INSTALL DETAILS 2023.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8655_R6_AE_SSr FL 8655.3 REPORT AND INSTALL DETAILS 2023.pdf Created by Independent Third Party: Yes |
|
|
| 8655.4 |
1.75 Snap Lock |
1 3/4" Snap Lock 18" over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-74.25psf Other: -74.25 psf @24" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL8655_R6_II_SSr FL 8655.4 REPORT AND INSTALL DETAILS 2023.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8655_R6_AE_SSr FL 8655.4 REPORT AND INSTALL DETAILS 2023.pdf Created by Independent Third Party: Yes |