FL # FL27659-R2
Application Type Affirmation
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Sierra Pacific Windows
Address/Phone/Email 11605 Reading Road
PO Box 8489
Red Bluff, CA 96080
(715) 748-1716
jgouza@spi-ind.com
 
Authorized Signature Gouza Jessica
jgouza@spi-ind.com
 
Technical Representative Cheryl Wibben
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1742
cwibben@spi-ind.com
 
Quality Assurance Representative Jessica Gouza
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1716
jgouza@spi-ind.com
 
Category Windows
Subcategory Casement
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A440-112011
ASTM E1886-13a2013
ASTM E1996-142014
TAS 201/202/203-942014
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 08/24/2023
Date Validated 08/24/2023
Date Pending FBC Approval
Date Approved 09/09/2023
Date Revised 09/20/2025
 
Summary of Products
FL # Model, Number or Name Description
27659.1 FeelSafe Aluminum Clad Casement FeelSafe Aluminum Clad Casement 108.5"x 104.75" (3-Wide x 2-High)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Span 108.5"; Trib Width 52.5"; Glass make up Type AA [15/16" Insul--3mm Temp Interior Lite; .438 XL Edge spacer; 8.6mm Annealed Lami (3mm AN; .090" Saflex PVB; 3mm AN Ext. Lite)]; Complies with ASTM E1300 requirements; Meets large missile requirement as stated in FBC section 2411.3.3.7.
Certification Agency Certificate
 FL27659_R2_C_CAC_436-H-105.73-75.pdf
Quality Assurance Contract Expiration Date
 06/09/2026
Installation Instructions
 FL27659_R2_II_FeelSafe Casement 109x105 3w2h CCL 436-H-105.73 ESP020765P-1769.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
27659.2 FeelSafe Aluminum Clad Casement FeelSafe Aluminum Clad Casement 125.38"x 84.19" 3-Wide Operator/Picture
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-70
 Other: Span 84.19"; Trib width 44.5"; Glass make up Operator Type C--Monolithic 11.9mm (15/32") Annealed Lami (5mm AN; .090" Saflex PVB Interlayer; 5mm AN)-Picture Type C--Monolithic 11.9mm (15/32") Annealed Lami (5mm AN; .090" Saflex PVB Interlayer; 5mm AN); Complies with ASTM E1300 requirements; Meets large missile requirement as stated in FBC section 2411.3.3.7.
Certification Agency Certificate
 FL27659_R2_C_CAC_436-H-105.56-58-63 CCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2025
Installation Instructions
 FL27659_R2_II_FeelSafe Casement 3-wide pic-op-op CCL436-H-105_56 ESP024728P-2111_1 Rev C.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
27659.3 FeelSafe Aluminum Clad Casement FeelSafe Aluminum Clad Casement 72.63"x 146.38" (2-Wide w/Single Stack)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-70
 Other: Span 72.63"; Trib width 73.25"; Glass make up Operator Glass Type CC [1-1/32" Insul--4mm Temp Interior Lite; .438" XL Edge spacer; 10.3 AN Lami (4mm AN; .090" Saflex PVB; 4mm AN Ext. Lite)] -Picture Glass Type HH [1-1/4" Insul--6mm Temp Interior Lite; .438" XL Edge spacer; 14.1mm Heat Strengthened Lami (6mm HS; .075" Storm; 6mm HS Ext. Lite)] ; Complies with ASTM E1300 requirements; Meets large missile requirements as stated in FBC section 2411.3.3.7.
Certification Agency Certificate
 FL27659_R2_C_CAC_436-H-105.59-62-64 CCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2025
Installation Instructions
 FL27659_R2_II_FeelSafe Casement 2-Wide stacked below 1-Wide Direct Set CCL436-H-105.59_62 ESP024728P-2111_1 Rev D.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
27659.4 FeelSafe Aluminum Clad Casement FeelSafe Aluminum Clad Casement 72.63"x 143.38" (2-wide w/Single Stack)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-70
 Other: Span 84.19"; Trib width 36.19"; Glass make up Operator Type CC [1-1/32" Insul--4mm Temp Interior Lite; .438" XL Edge spacer; 10.3 AN Lami (4mm AN; .090" Saflex PVB; 4mm AN Ext. Lite)] Picture Type HH [1-1/4" Insul--6mm Temp Interior Lite; .438" XL Edge spacer; 14.1mm Heat Strengthened Lami (6mm HS; .075" Storm; 6mm HS Ext. Lite)]; Complies with ASTM E1300 requirements; Meets large missile requirements as stated in FBC section 2411.3.3.7.
Certification Agency Certificate
 FL27659_R2_C_CAC_436-H-105.60-62-64 CCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2025
Installation Instructions
 FL27659_R2_II_FeelSafe Casement 2-Wide stacked below 1-Wide Direct Set CCL436-H-105.59_62 ESP024728P-2111_1 Rev D.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex