| 27665.1 |
Vinyl Designer Single Hung |
Vinyl Designer Single Hung 47.5"x 77.5"-Single-Pass Thru Unit |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27665_R3_C_CAC_448-H-002.29.pdf Quality Assurance Contract Expiration Date 02/16/2028 Installation Instructions FL27665_R3_II_8000 Vinyl Designers SH OP 48x78 CCL 448-H-002_28 ESP027657P-2260 Pass-Through Unit.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27665.2 |
Vinyl Designer Single Hung |
Vinyl Designer Single Hung 2-Wide w/2-Wide Transom 71.5"x 95.5" (36"x 72"/24") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27665_R3_C_CAC_448-H-002.33.pdf Quality Assurance Contract Expiration Date 03/20/2028 Installation Instructions FL27665_R3_II_8000 Vinyl Designers SH OP-Pic 2W2H 71.5X95.5 CCL448-H-002.32 ESP028012P-2286.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27665.3 |
Vinyl Designer Single Hung Picture |
Vinyl Designer Single Hung 47.5"x 83.5"-Single |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27665_R3_C_CAC_448-H-002.26.pdf Quality Assurance Contract Expiration Date 03/20/2028 Installation Instructions FL27665_R3_II_8000 Vinyl Designers SH OP 48x84 CCL 448-H-002_25 ESP027888P-2277.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |