|
|
| 27661.1 |
Aluminum Clad Casement Corner |
Aluminum Clad Casement Corner 96"x 75" (48"/48"x 75) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_429-H-514.04.pdf Quality Assurance Contract Expiration Date 09/22/2027 Installation Instructions FL27661_R3_II_429-H-514.04C-DG-CP Nail Fin Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.2 |
Aluminum Clad Casement Picture |
Aluminum Clad Casement Picture 72.1875"x 72.1875" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_436-H-109.19 CCL.pdf Quality Assurance Contract Expiration Date 04/19/2028 Installation Instructions FL27661_R3_II_Clad Casement Picture 72x72 CCL 436-H-109.18 ESP028144P-2299.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.3 |
H3 2.0 Casement Picture |
H3 2.0 Casement Picture 59.5"x 100" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_436-H-660.102.pdf Quality Assurance Contract Expiration Date 07/24/2028 Installation Instructions FL27661_R3_II_H3 2.0 Casement Picture 59.5 x100 CCL436-H-660.101 - .105 ESP028900P-2339.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.4 |
H3 2.0 Casement Picture |
H3 2.0 Casement Picture 59.5"x 100"-HP |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Requires installation straps; Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_436-H-660.106.pdf Quality Assurance Contract Expiration Date 07/24/2028 Installation Instructions FL27661_R3_II_H3 2.0 Casement Picture 59.5 x100 CCL436-H-660.101 - .105 ESP028900P-2339.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.5 |
H3 2.0 Casement Picture |
H3 2.0 Casement Picture 71.5"x 83.5" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_436-H-660.94.pdf Quality Assurance Contract Expiration Date 05/01/2028 Installation Instructions FL27661_R3_II_H3 2.0 Casement Picture 72x84 CCL 436-H-660.93 .97 ESP028203P-2305.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.6 |
H3 2.0 Casement Picture |
H3 2.0 Casement Picture 71.5"x 83.5" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Requires installation straps; Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_436-H-660.98.pdf Quality Assurance Contract Expiration Date 05/01/2028 Installation Instructions FL27661_R3_II_H3 2.0 Casement Picture 72x84 CCL 436-H-660.93 .97 ESP028203P-2305.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.7 |
Vinyl Designer Single Hung Picture |
Vinyl Designer Single Hung Picture 52.25" x 83.5" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_448-H-007.05.pdf Quality Assurance Contract Expiration Date 03/19/2028 Installation Instructions FL27661_R3_II_8000 Vinyl Designer SH Pic 52x84 CCL 448-H-007_04 ESP027887P-2276.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.8 |
Vinyl Premium Double Hung Picture |
Vinyl Premium Double Hung Picture 59.5"x 83.5" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_448-H-010.07.pdf Quality Assurance Contract Expiration Date 06/20/2028 Installation Instructions FL27661_R3_II_8000 Vinyl Premium Pic 60x84 CCL 448-H-010.06 .10 ESP28132P-2296.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27661.9 |
Vinyl Premium Double Hung Picture |
Vinyl Premium Double Hung Picture 59.5"x 83.5" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL27661_R3_C_CAC_448-H-010.11.pdf Quality Assurance Contract Expiration Date 06/20/2028 Installation Instructions FL27661_R3_II_8000 Vinyl Premium Pic 60x84 CCL 448-H-010.06 .10 ESP28132P-2296.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |