| 9329.1 |
26 Ga. ¾” Rib Roof Panel |
26 Ga. ¾” Rib Roof Panel over 1x4 SYP Wood Purlins over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.25 Other: -106.75 PSF @ 9"-9"-9"-9" fastener pattern @ 24" O.C. fastener spacing. -164.25 PSF @ 9"-9"-9"-9" fastener pattern @ 12" O.C. fastener spacing. Install per manufacturers details and in compliance with CURRENT FBC . For use in HVHZ Zone. |
Installation Instructions FL9329_R6_II_SS FL 9329 2023 METAL MAX LLC REPORTS AND INSTALL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL9329_R6_AE_SS FL 9329 2023 METAL MAX LLC REPORTS AND INSTALL.pdf Created by Independent Third Party: Yes |
|
|
| 9329.2 |
29 Ga. ¾” Rib Roof Panel |
29 Ga. ¾” Rib Roof Panel over 1x4 SYP Wood Purlins over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 9”-9”-9”-9” Fastener Pattern at 24” O.C.
-116.0 psf @ 6.5”-2.5”-6.5”-2.5”-6.5”-2.5”-6.5” Fastener Pattern at 24” O.C. Install per manufacturer detail and in compliance with CURRENT FBC . Not for use in HVHZ Zones. |
Installation Instructions FL9329_R6_II_SS FL 9329 2023 METAL MAX LLC REPORTS AND INSTALL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL9329_R6_AE_SS FL 9329 2023 METAL MAX LLC REPORTS AND INSTALL.pdf Created by Independent Third Party: Yes |
|
|
| 9329.3 |
5V Crimp |
26 Ga. 5V Crimp Roof Panel over 15/32” APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12” O.C. Fastener Spacing. -156.5 psf @ 6” O.C. Fastener Spacing. Install per manufacturers details and in compliance with CURRENT FBC . For use in HVHZ Zones. |
Installation Instructions FL9329_R6_II_SS FL 9329 2023 METAL MAX LLC REPORTS AND INSTALL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL9329_R6_AE_SS FL 9329 2023 METAL MAX LLC REPORTS AND INSTALL.pdf Created by Independent Third Party: Yes |