| 24397.1 |
5V Crimp |
0.032" Aluminum - 5V Crimp 24" Wide Roof Panels Over 1/2" Plywood, Fastened 12" O.C. x 14" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71.0 Other: |
Installation Instructions FL24397_R9_II_3971 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3971 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.2 |
5V Crimp |
26 Ga. Steel - 5V Crimp 24" Wide Roof Panels Over Nominal 7/16" OSB Sheathing, Fastened 12" O.C. x 16" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: |
Installation Instructions FL24397_R9_II_3972 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3972 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.3 |
5V Crimp |
26 Ga. Steel - 5V Crimp 24" Wide Roof Panels Over Nominal 7/16" OSB Sheathing, Fastened (2) 12" O.C. x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: |
Installation Instructions FL24397_R9_II_3973 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3973 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.4 |
Armour Loc 0.032" Aluminum |
0.032" Aluminum - 1" Nailstrip x 16" Wide Roof Panels Over 1/2" Plywood, Fastened 4 5/8" O.C.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: |
Installation Instructions FL24397_R9_II_3974 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3974 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.5 |
Armour Loc 26 Ga. |
26 Ga. Steel - 1" Nailstrip x 16" Wide Roof Panels Over 1/2" Plywood, Fastened 4 3/4" O.C.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0 Other: |
Installation Instructions FL24397_R9_II_3975 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3975 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.6 |
Armour PBR |
26 Ga. Steel - PBR 1 1/8" x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 12" O.C. x 24" O.C.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: |
Installation Instructions FL24397_R9_II_3976 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3976 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.7 |
Armour Rib 0.032" Aluminum |
0.032" Aluminum - 3/4" Rib x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 9" O.C. x 6" O.C.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: |
Installation Instructions FL24397_R9_II_3977 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3977 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.8 |
Armour Rib 29 Ga. |
29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 9" O.C. x 24" O.C.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: |
Installation Instructions FL24397_R9_II_3978 Dwg3.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3978 Eval3.pdf Created by Independent Third Party: Yes |
|
|
| 24397.9 |
Armour Rib 29 Ga. |
29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1/2" Plywood, Fastened 6"-3"-6" O.C. x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: |
Installation Instructions FL24397_R9_II_3979 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_3979 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.10 |
Armour Rib 29 Ga. |
29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1x4 Wood Battens Over 1/2" Plywood, Fastened 9" O.C. x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: |
Installation Instructions FL24397_R9_II_39710 Dwg3.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_39710 Eval3.pdf Created by Independent Third Party: Yes |
|
|
| 24397.11 |
Armour Rib 29 Ga. |
29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 1x4 Wood Battens Over 1/2" Plywood, Fastened 6"-3"-6" O.C. x 24" O.C. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: |
Installation Instructions FL24397_R9_II_39711 Dwg2.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_39711 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 24397.12 |
Armour Rib 29 Ga. |
29 Ga. Steel - 3/4" Rib x 36" Wide Roof Panels Over 19/32" OSB Sheathing, Fastened 9" O.C. x 24" O.C.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: |
Installation Instructions FL24397_R9_II_39712 Dwg3.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL24397_R9_AE_39712 Eval3.pdf Created by Independent Third Party: Yes |