| 11002.1 |
Heritage Series Fixed Inswing Casement |
96" x 72" Non-Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass complies with the current ASTM E1300 standard; 7/8" IG, 3/16" Heat Strength x 3/16" Heat Strength |
Certification Agency Certificate FL11002_R11_C_CAC_24115 CCL.pdf Quality Assurance Contract Expiration Date 05/05/2035 Installation Instructions FL11002_R11_II_24115 String.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 11002.2 |
Heritage Series Operating Casement |
36" x 72", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Glass complies with the current ASTM E1300 standard (3.1-8.0 SS-3.9 .090" SGP 3.9 and 3.9 TE-8.0 SS-3.9 .090" SGP 3.9) Insulated Glass, Wood Frame, Wind Zone 4 Missile D, Maple Core Sash |
Certification Agency Certificate FL11002_R11_C_CAC_25067 CCL.pdf Quality Assurance Contract Expiration Date 04/10/2036 Installation Instructions FL11002_R11_II_25067 String.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 11002.3 |
Heritage Series Operating Inswing Casement |
36" x 72" Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20/-20 Other: Glass complies with the current ASTM E1300 standard; Positive design pressure +20 psf |
Certification Agency Certificate FL11002_R11_C_CAC_CCL 23006 recert 11002.pdf Quality Assurance Contract Expiration Date 09/26/2033 Installation Instructions FL11002_R11_II_12202 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 11002.4 |
Ultra Series Operating Casement |
36" x 90" Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Glass complies with the current ASTM E1300 standard
|
Certification Agency Certificate FL11002_R11_C_CAC_CCL 22046 recert 12074.pdf Quality Assurance Contract Expiration Date 11/10/2032 Installation Instructions FL11002_R11_II_12074 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 11002.5 |
Ultra Series Operating Casement Half Circle |
36" x 90" Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: Glass complies with the current ASTM E1300 standard
|
Certification Agency Certificate FL11002_R11_C_CAC_CCL 22040 recert 12084.pdf Quality Assurance Contract Expiration Date 02/21/2033 Installation Instructions FL11002_R11_II_12084 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 11002.6 |
Ultra Series Operating Casement Quarter Circle |
36" x 90" Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass complies with the current ASTM E1300 standard |
Certification Agency Certificate FL11002_R11_C_CAC_22042 CCL.pdf Quality Assurance Contract Expiration Date 02/21/2033 Installation Instructions FL11002_R11_II_22042 String.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 11002.7 |
Ultra Series Operating Casement Segment Head |
36" x 90" Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-70 Other: Glass complies with the current ASTM E1300 standard
|
Certification Agency Certificate FL11002_R11_C_CAC_CCL 22041 recert 12101.pdf Quality Assurance Contract Expiration Date 02/21/2033 Installation Instructions FL11002_R11_II_12101 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |