Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL21160-R3
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Sierra Pacific Windows
Address/Phone/Email 11605 Reading Road
PO Box 8489
Red Bluff, CA 96080
(715) 748-1716
jgouza@spi-ind.com
 
Authorized Signature Gouza Jessica
jgouza@spi-ind.com
 
Technical Representative Cheryl Wibben
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1742
cwibben@spi-ind.com
 
Quality Assurance Representative Jessica Gouza
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1716
jgouza@spi-ind.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402008
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 11/20/2023
Date Validated 11/27/2023
Date Pending FBC Approval
Date Approved 11/28/2023
Date Revised 07/16/2026
 
Summary of Products
FL # Model, Number or Name Description
21160.1 H3 2.0 Double Hung Picture H3 2.0 Double Hung Picture Single 72"x84" (HP)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Maximum individual frame size 72:x84" (1816mmx2121mm); Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21160_R3_C_CAC_436-H-674.05 CCL.pdf
Quality Assurance Contract Expiration Date
 03/04/2026
Installation Instructions
 FL21160_R3_II_H3 2.0 DH PIC 72X84 CCL 436-H-674_04 ESP022243P-1878 Rev 10-12-23.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21160.2 H3 2.0 Double Hung Picture H3 2.0 Double Hung Picture Single 60"x80"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-65
 Other: Maximum individual frame size 60"x80" (15811mmx2019mm); Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21160_R3_C_CAC_436-H-674.08 CCL.pdf
Quality Assurance Contract Expiration Date
 04/22/2026
Installation Instructions
 FL21160_R3_II_H3 2.0 DH PIC 60X80 CCL 436-H-674.08 ESP022629P-1919 Rev 10-12-23.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 