| 32362.1 |
AAP-100 (Rainscreen) Wall Cladding System |
4mm Alucobond Panel System with Extruded Aluminum Framing (SMI) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +130/-130 Other: Please see Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL32362_R3_II_AAP100 Dwg2.pdf Verified By: Scott Wolters FL PE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL32362_R3_AE_AAP100 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 32362.2 |
AAP-100 (Rainscreen) Wall Cladding System |
4mm Alucobond Panel System with Extruded Aluminum Framing (LMI) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +150/-150 Other: Please see Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL32362_R3_II_AAP100LMI Dwg.pdf Verified By: Scott Wolters FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL32362_R3_AE_AAP100LMI Eval.pdf Created by Independent Third Party: Yes |
|
|
| 32362.3 |
AAP-700 (Male/Female) Wall Cladding System |
4mm Alucobond Panel System with Extruded Aluminum Framing (SMI) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +130/-130 Other: Please see Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL32362_R3_II_AAP700 Dwg2.pdf Verified By: Scott Wolters FL PE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL32362_R3_AE_AAP700 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 32362.4 |
AAP-900 (Wet Seal) Wall Cladding System |
1/8" Aluminum Panel System (SMI) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +130/-130 Other: Please see Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL32362_R3_II_AAP900 Dwg2.pdf Verified By: Scott Wolters FL PE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL32362_R3_AE_AAP900 Eval2.pdf Created by Independent Third Party: Yes |
|
|
| 32362.5 |
AAP-950 (Dry Joint) Wall Cladding System |
1/8" Aluminum Panel System (SMI) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +130/-130 Other: Please See Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL32362_R3_II_AAP950 Dwg2.pdf Verified By: Scott Wolters FL PE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL32362_R3_AE_AAP950 Eval2.pdf Created by Independent Third Party: Yes |