| 32326.1 |
American & European series standard direct set wood window |
Standard direct glaze fixed window (Small & Large Missile Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Window size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1323. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL32326_R3_II_Anchor requirements in saltwater coastline areas (1).pdf FL32326_R3_II_Drawing 1323.pdf Verified By: Warren W. Schaefer, P.E. PE-44135 Created by Independent Third Party: Yes Evaluation Reports FL32326_R3_AE_Evaluation report WWS-360.pdf Created by Independent Third Party: Yes |
|
|
| 32326.2 |
American series in-swing wood fixed casement window |
In-swing fixed casement window (Small & Large Missile Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Window size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1322A. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL32326_R3_II_Anchor requirements in saltwater coastline areas (1).pdf FL32326_R3_II_Drawing 1322A.pdf Verified By: Warren W. Schaefer, P.E. PE-44135 Created by Independent Third Party: Yes Evaluation Reports FL32326_R3_AE_Evaluation report WWS-364.pdf Created by Independent Third Party: Yes |
|
|
| 32326.3 |
American series out-swing wood fixed casement window |
Out-swing fixed casement window (Small & Large Missile Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Window size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1322. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL32326_R3_II_Anchor requirements in saltwater coastline areas (1).pdf FL32326_R3_II_Drawing 1322.pdf Verified By: Warren W. Schaefer, P.E. PE-44135 Created by Independent Third Party: Yes Evaluation Reports FL32326_R3_AE_Evaluation report WWS-363.pdf Created by Independent Third Party: Yes |
|
|
| 32326.4 |
Large direct set window |
Large direct glaze fixed window (Small & Large Missile Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Window size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1918. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL32326_R3_II_Anchor requirements in saltwater coastline areas (1).pdf FL32326_R3_II_Drawing 1918.pdf Verified By: Warren W. Schaefer, P.E. PE-44135 Created by Independent Third Party: Yes Evaluation Reports FL32326_R3_AE_Evaluation report WWS-377.pdf Created by Independent Third Party: Yes |