| 3155.1 |
Versapanel 1-3/4" |
Insulated Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This panel is for wall applications only and is NOT for use in High Velocity Hurricane Zones (HVHZ). The wind load capacity of this panel must be in accordance with the load/span tables of Appendix A, B or C of Product Evaluation Report No. 2615. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL3155_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf FL3155_R9_II_Versapanel Wall Florida Non HVHZ_ss.pdf Verified By: Robert J. Amoruso, P.E. FL P.E. No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL3155_R9_AE_ACE-PER-2615_Rev3_Versapanel Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 3155.2 |
Versapanel 2-1/2" |
Insulated Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This panel is for wall applications only and is NOT for use in High Velocity Hurricane Zones (HVHZ). The wind load capacity of this panel must be in accordance with the load/span tables of Appendix A, B or C of Product Evaluation Report No. 2615. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL3155_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf FL3155_R9_II_Versapanel Wall Florida Non HVHZ_ss.pdf Verified By: Robert J. Amoruso, P.E. FL P.E. No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL3155_R9_AE_ACE-PER-2615_Rev3_Versapanel Wall Panel_Appendices_ss.pdf Created by Independent Third Party: No |
|
|
| 3155.3 |
Versapanel 4" |
Insulated Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This panel is for wall applications only and is NOT for use in High Velocity Hurricane Zones (HVHZ). The wind load capacity of this panel must be in accordance with the load/span tables of Appendix A, B or C of Product Evaluation Report No. 2615. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL3155_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf FL3155_R9_II_Versapanel Wall Florida Non HVHZ_ss.pdf Verified By: Robert J. Amoruso, P.E. FL P.E. No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL3155_R9_AE_ACE-PER-2615_Rev3_Versapanel Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 3155.4 |
Versawall 2" |
Insulated Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This panel is for wall applications only and is NOT for use in High Velocity Hurricane Zones (HVHZ). The wind load capacity of this panel must be in accordance with the load/span tables of Appendix A or B of Product Evaluation Report No. 2589. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL3155_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf FL3155_R9_II_VW Florida non-HVHZ_OriginalIssue_ss.pdf Verified By: Robert J. Amoruso, P.E. FL PE 49752 Created by Independent Third Party: Yes Evaluation Reports FL3155_R9_AE_ACE-PER-2589_Rev3_VersaWall Panel_Appendix A and B_ss.pdf Created by Independent Third Party: Yes |
|
|
| 3155.5 |
Versawall 2-3/4" |
Insulated Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This panel is for wall applications only and is NOT for use in High Velocity Hurricane Zones (HVHZ). The wind load capacity of this panel must be in accordance with the load/span tables of Appendix A or B of Product Evaluation Report No. 2589. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL3155_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf FL3155_R9_II_VW Florida non-HVHZ_OriginalIssue_ss.pdf Verified By: Robert J. Amoruso, P.E. FL PE 49752 Created by Independent Third Party: Yes Evaluation Reports FL3155_R9_AE_ACE-PER-2589_Rev3_VersaWall Panel_Appendix A and B_ss.pdf Created by Independent Third Party: Yes |
|
|
| 3155.6 |
Versawall 4" |
Insulated Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This panel is for wall applications only and is NOT for use in High Velocity Hurricane Zones (HVHZ). The wind load capacity of this panel must be in accordance with the load/span tables of Appendix A or B of Product Evaluation Report No. 2589. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL3155_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf FL3155_R9_II_VW Florida non-HVHZ_OriginalIssue_ss.pdf Verified By: Robert J. Amoruso, P.E. FL PE 49752 Created by Independent Third Party: Yes Evaluation Reports FL3155_R9_AE_ACE-PER-2589_Rev3_VersaWall Panel_Appendix A and B_ss.pdf Created by Independent Third Party: Yes |