| 40077.1 |
1.5" Nailstrip Standing Seam 24 Ga. Roof Panel over 15/32 Plywood |
1.5" Nailstrip Standing Seam 24 Ga. Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0psf Other: -131.0psf @ 4 5/8" O.C.
-101.2psf @ 9 1/4" O.C.
-71.5psf @ 13 7/8" O.C.
-41.7psf @ 18 1/2" O.C. |
Installation Instructions FL40077_R1_II_Naisltrip Standing Seam 24 Ga. over Plywood.pdf Verified By: Johnathan E. Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL40077_R1_AE_Naisltrip Standing Seam 24 Ga. over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 40077.2 |
26 Ga. PBR Roof Panel over Plywood |
26 Ga. PBR Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-41.7psf Other: Panel Installed over 15/32" Plywood
-108.5 psf @ 12" O.C.
-88.5 psf @ 18" O.C.
-68.4 psf @ 24" O.C.
-41.7 psf @ 32" O.C.
Panel Installed over 19/32" Plywood
-183.5 psf @ 12" O.C.
-149.8 psf @ 18" O.C.
-116.0 psf @ 24" O.C.
-71.0 psf @ 32" O.C. |
Installation Instructions FL40077_R1_II_26 Ga. PBR over Plywood.pdf Verified By: Johnathan E. Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL40077_R1_AE_26 Ga. PBR over Plywood.pdf Created by Independent Third Party: Yes |