| 27204.1 |
Min. 26 Ga. 5V Crimp Roof Panel |
Min. 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97.5 psf Other: -57.5 psf at 36" o.c. -77.5 psf at 30" o.c. -97.5 psf at 24" o.c. -117.5 psf at 18" o.c. -137.5 psf at 12" o.c. Install per Manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL27204_R3_II_26 Ga. 5V Crimp Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL27204_R3_AE_26 Ga. 5V Crimp Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 27204.2 |
Min. 26 Ga. Goldin Roof Panel |
Min. 26 Ga. Goldin Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-85.0 psf Other: -85.0 psf at 24" o.c. -102.9 psf at 18" o.c. -120.7 psf at 12" o.c. Install per Manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL27204_R3_II_26 Ga. Goldin Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL27204_R3_AE_26 Ga. Goldin Panel over Plywood.pdf Created by Independent Third Party: Yes |