FL # FL27204-R4
Application Type Revision
Code Version 2026
Application Status Pending FBC Approval
 
Comments
Archived
 
Product Manufacturer Goldin Metals, Inc.
Address/Phone/Email 14231 Seaway Road, Suite 7000
Gulfport, MS 39503
(228) 896-6216
jasongoldin@goldinmetals.com
 
Authorized Signature Jason Goldin
jasongoldin@goldinmetals.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 01/04/2029
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL27204_R4_COI_Letter of Certification.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/20/2026
Date Validated 09/21/2026
Date Pending FBC Approval 09/26/2026
 
Summary of Products
FL # Model, Number or Name Description
27204.1 Min. 26 Ga. 5V Crimp Roof Panel Min. 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-97.5 psf
 Other: -57.5 psf at 36" o.c. -77.5 psf at 30" o.c. -97.5 psf at 24" o.c. -117.5 psf at 18" o.c. -137.5 psf at 12" o.c. Install per Manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL27204_R4_II_26 Ga. 5V Crimp Panel over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL27204_R4_AE_26 Ga. 5V Crimp Panel over Plywood.pdf
 Created by Independent Third Party: Yes
27204.2 Min. 26 Ga. Goldin Roof Panel Min. 26 Ga. Goldin Roof Panel over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-85.0 psf
 Other: -85.0 psf at 24" o.c. -102.9 psf at 18" o.c. -120.7 psf at 12" o.c. Install per Manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL27204_R4_II_26 Ga. Goldin Panel over Plywood.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL27204_R4_AE_26 Ga. Goldin Panel over Plywood.pdf
 Created by Independent Third Party: Yes
 