| 5562.1 |
1. Tite-Loc-Plus Steel Panel |
2" High, 18" Wide x 24 Ga. (min.) Steel Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-99.4 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Uplift load of 31.8 psf @ clip spacing of 5'-0" o.c. and 99.4 psf @ clip spacing of 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R12_II_EvaluationReportC3073_1.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R12_AE_EvaluationReportC3073_1.pdf Created by Independent Third Party: Yes |
|
|
| 5562.2 |
2. Tite-Loc-Plus Aluminum Panel |
2" High, 16" Wide x 0.032" (min.) Aluminum Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.4 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Uplift load of 23.6 psf @ clip spacing of 5'-0" o.c. and 57.4 psf @ clip spacing of 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R12_II_EvaluationReportC3073_2.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R12_AE_EvaluationReportC3073_2.pdf Created by Independent Third Party: Yes |
|
|
| 5562.3 |
3. Tite-Loc-Plus Aluminum Panel |
2" High, 18" Wide x 0.032" (min.) Aluminum Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.2 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Uplift load of 21.0 psf @ clip spacing of 5'-0" o.c. and 52.2 psf @ clip spacing of 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R12_II_EvaluationReportC3073_3.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R12_AE_EvaluationReportC3073_3.pdf Created by Independent Third Party: Yes |
|
|
| 5562.4 |
4. Tite-Loc-Plus Aluminum Panel |
2" High, 18" Wide x 0.040" (min.) Aluminum Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-202.5 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Uplift load of 56.0 psf @ clip spacing of 5'-0" o.c. and 202.5 psf @ clip spacing of 1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R12_II_EvaluationReportC3073_4.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R12_AE_EvaluationReportC3073_4.pdf Created by Independent Third Party: Yes |