Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL6276-R14
Application Type Revision
Code Version 2026
Application Status Pending FBC Approval
 
Comments
Archived
 
Product Manufacturer ICP Construction, Inc.
Address/Phone/Email 2775 Barber Road
Norton, OH 44203
(330) 753-4585   Ext 1108
mkeen@icpgroup.com
 
Authorized Signature Mark Keen
mkeen@icpgroup.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Roof Tile Adhesives
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity IAPMO Quality Control Consultants, LLC
Quality Assurance Contract Expiration Date 06/30/2027
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL6276_R14_COI_2024_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D16222014
ASTM D16232017
ASTM D21262015
ASTM D28422012
ASTM D28561998
ASTM E962024
SSTD 111997
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/06/2026
Date Validated 10/08/2026
Date Pending FBC Approval 10/17/2026
 
Summary of Products
FL # Model, Number or Name Description
6276.1 APOC POLYSET RTA-1 Single component polyurethane foam roof tile adhesive for use in FBC non-HVHZ jurisdictions.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-349
 Other: 1.) The design pressure limitation in this application refers to hip and ridge tiles. Field tiles are designed based on overturning moment resistance. 2.) Refer to PEER Section 5 for other Limits of Use.
Installation Instructions
 FL6276_R14_II_2026_10_06_FINAL_PEER-ICP-003.B_RTA-1_FL6276-R14.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6276_R14_AE_2026_10_06_FINAL_PEER-ICP-003.B_RTA-1_FL6276-R14.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex