| 9557.1 |
7/8" Corrugated Panels |
Min. 26 ga., maximum 37.33" wide coverage through fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +110.5/-140 Other: Maximum outward load of 140 psf for 24 ga. panel at support spacing of 2’ o.c. |
Installation Instructions FL9557_R5_II_EvaluationReportC2372_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9557_R5_AE_EvaluationReportC2372_1.pdf Created by Independent Third Party: Yes |
|
|
| 9557.2 |
FL100 |
Min 24 ga. steel or 0.032" thick aluminum, 12" wide concealed fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +60/-90 Other: Inward load of 60 psf and outward load of 90 psf at support spacing of 2' for steel panels. |
Installation Instructions FL9557_R5_II_EvaluationReportC2372_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9557_R5_AE_EvaluationReportC2372_2.pdf Created by Independent Third Party: Yes |
|
|
| 9557.3 |
MasterRib Panel |
29 ga., 36" wide wall panel over steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +45.35/-37.7 Other: Design load of 45.35 & - 37.7 psf at support spacing of 48" o.c. |
Installation Instructions FL9557_R5_II_EvaluationReportC2372_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9557_R5_AE_EvaluationReportC2372_3.pdf Created by Independent Third Party: Yes |
|
|
| 9557.4 |
MasterRib Panel |
29 ga., 36" wide wall panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +45.35/-36.2 Other: Design load of 45.35 & - 36.2 psf at support spacing of 48" o.c. |
Installation Instructions FL9557_R5_II_EvaluationReportC2372_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9557_R5_AE_EvaluationReportC2372_4.pdf Created by Independent Third Party: Yes |
|
|
| 9557.5 |
R or PBR Panel |
Min 26 ga., 36" wide wall panel fastened to steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +96/-163 Other: Design loads of 96 and -163 psf at support spacing of 20" o.c. |
Installation Instructions FL9557_R5_II_EvaluationReportC2372_5.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL9557_R5_AE_EvaluationReportC2372_5.pdf Created by Independent Third Party: Yes |