FL # FL18022-R3
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer GlassCraft Door Corporation
Address/Phone/Email 2002 Brittmoore Road
Houston, TX 77043-2209
(713) 690-8282
dans@glasscraft.net
 
Authorized Signature Dan Sitkowski
dans@glasscraft.net
 
Technical Representative Daniel Sitkowski
Address/Phone/Email 2002 Brittmoore Rd.
Houston, TX 77043
(713) 997-9107
dans@glasscraft.net
 
Quality Assurance Representative Rita Freeman
Address/Phone/Email 2002 Brittmoore Rd
Houston, TX 77043
(713) 690-8282   Ext 261
ritaf@glasscraft.net
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - Plano, TX
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2027
Validated By Jesus Gonzalez, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL18022_R3_COI_Certificate of Independence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E3302014
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL18022_R3_Equiv_ASTM E330 Equivalency Letter.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 12/26/2023
Date Validated 01/28/2024
Date Pending FBC Approval 02/03/2024
Date Approved 04/16/2024
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
18022.1 07 - Estancia In Swing Double Doors Estancia in swing double doors with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64137.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_64137.01-801-44-r1.pdf
18022.2 08 - Estancia in swing single doors Estancia in swing single doors with or without sidelights with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64141.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_64141.01-801-44-r1.pdf
18022.3 09 - Estancia Out Swing Double Doors Estancia out swing double doors with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64138.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_64138.01-801-44-r1.pdf
18022.4 10 - Estancia out swing single doors Estancia out swing single doors with or without sidelights with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-457
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64142.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_64142.01-801-44-r1.pdf
18022.5 11 - Portobello in swing double doors Portobello in swing double doors with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64137.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Fridley, MN
Test Reports
 FL18022_R3_TR_64137.01-801-44-r1.pdf
18022.6 12 - Portobello In swing single doors All Portobello in swing single doors with or without sidelights and with or without transom.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64141.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Fridley, MN
Test Reports
 FL18022_R3_TR_64141.01-801-44-r1.pdf
18022.7 13 - Portobello Out Swing Double Doors Portobello out swing double doors with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64138.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_64138.01-801-44-r1.pdf
18022.8 14 - Portobello out swing single doors Portobello out swing doors with or without sidelights with or without transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.2/-45.7
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_64142.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_64142.01-801-44-r1.pdf
18022.9 15 - Estancia Hardwood Door Estancia 42" x 8' or smaller in swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_69320.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_69320.01-801-44-r3.pdf
18022.10 16 - Estancia Hardwood Doors Estancia 42" x 8' or smaller out swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_69316.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_69316.01-801-44-r3.pdf
18022.11 17 - Portobello Hardwood Doors Portobello 42" x 8' or smaller out swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_69316.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_69316.01-801-44-r3.pdf
18022.12 18 - Portobello Hardwood Doors Portobello 42" x 8' or smaller in swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_69320.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_69320.01-801-44-r3.pdf
18022.13 19 - Mahogany Entry Door 6'x8' Double Inswing Hardwood TDL Door with Half Circle TDL Transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +44.24/-55.72
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_81839.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_81839.01-801-44-r3.pdf
18022.14 20 - Mahogany Entry Door 6'x8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +44.24/-55.72
 Other: Not tested for air or water infiltration
Installation Instructions
 FL18022_R3_II_81838.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_81838.01-801-44-r3.pdf
18022.15 21 - Mahogany Entry Door 3'x8' Single Inswing TDL Hardwood Door with TDL Sidelites
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.18/-61.60
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_81840.01-801-44-r3.pdf
 Verified By: Intertek - Washington (ATI)
Test Reports
 FL18022_R3_TR_81840.01-801-44-r3.pdf
18022.16 22 - Mahogany Entry Door 3'x8' Single Outswing TDL Hardwood Door with TDL Sidelites
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.18/-61.6
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_81842.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_81842.01-801-44-r3.pdf
18022.17 23 - Fiberglass Door In-swing Fiberglass Glazed Double Doors
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +31.6/-34.6
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_B0805.01-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_B0805.01-801-44-r1.pdf
18022.18 24 - Fiberglass Door In-swing Fiberglass Door w/ Sidelites
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +31.6/-34.6
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_B0805.02-801-44-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_B0805.02-801-44-r1.pdf
18022.19 25 - Fiberglass Door In-swing Fiberglass Solid Double Doors
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +31.6/-34.6
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL18022_R3_II_B0805.03-801-44-r2.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_B0805.03-801-44-r2.pdf
18022.20 26 - 8'-0" Single Wood Door with Speak Easy
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40.10/-40.10
 Other: Inswing and Outswing
Installation Instructions
 FL18022_R3_II_D2058.01-801-44-R2.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL18022_R3_TR_D2058.01-801-44-R2.pdf