Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL4615-R4
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Lakeside Salvage / Lakeside Building Materials, Inc.
Address/Phone/Email 3894 Eufaula Avenue
Eufaula, AL 36027
(334) 688-0550
chipperlakeside@eufaula.rr.com
 
Authorized Signature Allen Brown
chipperlakeside@eufaula.rr.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2028
Validated By Brian Jaks, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL4615_R4_COI_Letter of Certification- Lakeside Salvage_sealed.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
FM 44711992
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/30/2020
Date Validated 10/07/2020
Date Pending FBC Approval 11/04/2020
Date Approved 12/15/2020
Date Revised 08/21/2025
 
Summary of Products
FL # Model, Number or Name Description
4615.1 Min. 26 Ga. ¾” Rib Min. 26 Ga. ¾” Rib Roof Panel over 15/32” Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-146.0PSF
 Other: -71.8 psf @ 24” O.C. Fastener Pattern: 9"-9"-"9-"9". -146.0 psf @ 12” O.C. Fastener Pattern: 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5" Install panel per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL4615_R4_II_FL4615.1 R4 Eval Report_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4615_R4_AE_FL4615.1 R4 Eval Report_sealed.pdf
 Created by Independent Third Party: Yes
4615.2 Min. 29 Ga. ¾” Rib Min. 29 Ga. ¾” Rib Roof Panel over 15/32” Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-146.0PSF
 Other: -69.3 psf @ 24” O.C. Fastener Pattern: 9"-9"-9"-9". -146.0 psf @ 12” O.C. Fastener Pattern: 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5". Install per manufacturer's details. Not for use in HVHZ Zones.
Installation Instructions
 FL4615_R4_II_FL4615.2 R4 Eval Report_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL4615_R4_AE_FL4615.2 R4 Eval Report_sealed.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex