| 4615.1 |
Min. 26 Ga. ¾” Rib |
Min. 26 Ga. ¾” Rib Roof Panel over 15/32” Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -71.8 psf @ 24” O.C. Fastener Pattern: 9"-9"-"9-"9". -146.0 psf @ 12” O.C. Fastener Pattern: 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5" Install panel per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4615_R4_II_FL4615.1 R4 Eval Report_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4615_R4_AE_FL4615.1 R4 Eval Report_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 4615.2 |
Min. 29 Ga. ¾” Rib |
Min. 29 Ga. ¾” Rib Roof Panel over 15/32” Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -69.3 psf @ 24” O.C. Fastener Pattern: 9"-9"-9"-9". -146.0 psf @ 12” O.C. Fastener Pattern: 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5". Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4615_R4_II_FL4615.2 R4 Eval Report_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4615_R4_AE_FL4615.2 R4 Eval Report_sealed.pdf Created by Independent Third Party: Yes |