| 30869.1 |
8217 Alum Clad Push-Out Awning (60x60) Single |
LC-PG50-AP 1511x1511 (60x60) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glazing utilizes 3/4" insulated glass comprised of two lites of 5/32" (3.9mm) annealed glass. Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL30869_R2_C_CAC_449-H-113.03 8217 Push-Out Awning 60x60.pdf Quality Assurance Contract Expiration Date 02/21/2029 Installation Instructions FL30869_R2_II_8217 Push-out Awning.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 30869.2 |
8219 Alum Clad Awning (60x48) Single & Mulled |
LC-PG50-3026x1207 (119x48) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glazing utilizes 3/4" insulated glass comprised of two lites of 1/8" (3mm) annealed glass. Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL30869_R2_C_CAC_449-H-111.03 Signature Twin Awning.pdf Quality Assurance Contract Expiration Date 04/05/2028 Installation Instructions FL30869_R2_II_8219 Mulled Casement - Awning.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 30869.3 |
8219 Alum Clad Awning (60x48) with stacked Casement Picture (60x60) |
LC-PG50-1511x2719 (60x107) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Awning glass utilized 3/4" insulated glass comprised of two lites of 1/8" (3mm) glass; " picture unit utilized 3/4" insulated glass comprised of two lites of 5/32" (3.9mm) annealed glass. Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL30869_R2_C_CAC_449-H-111.00, .01, .02 Signature Awning with Pic above.pdf Quality Assurance Contract Expiration Date 03/06/2028 Installation Instructions FL30869_R2_II_8219 Mulled Casement - Awning.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |