| 46727.1 |
MB-79N SI Fixed Window (HVHZ) (Impact) |
MB-79N SI Fixed Window (HVHZ) (Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See Installation Details and Evaluation Report for allowable design pressures, sizes, configurations, installation requirements and limits of use. |
Installation Instructions FL46727_R1_II_DRU033-A SS 2026-08-07.pdf Verified By: Hermes F. Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL46727_R1_AE_PER10889 SS 2026-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 46727.2 |
MB-79N SI Fixed Window (Non-HVHZ) (Non-Impact) |
MB-79N SI Fixed Window (Non-HVHZ) (Non-Impact) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Details and Evaluation Report for allowable design pressures, sizes, configurations, installation requirements and limits of use. |
Installation Instructions FL46727_R1_II_DRU034-A SS 2026-08-07.pdf Verified By: Hermes F. Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL46727_R1_AE_PER10890 SS 2026-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 46727.3 |
MB-86N SI Fixed Window (HVHZ) (Impact) |
MB-86N SI Fixed Window (HVHZ) (Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See Installation Details and Evaluation Report for allowable design pressures, sizes, configurations, installation requirements and limits of use. |
Installation Instructions FL46727_R1_II_DRU046-A SS 2026-08-07.pdf Verified By: Hermes F. Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL46727_R1_AE_PER10891 SS 2026-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 46727.4 |
MB-86N SI Fixed Window (Non-HVHZ) (Non-Impact) |
MB-86N SI Fixed Window (Non-HVHZ) (Non-Impact) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Details and Evaluation Report for allowable design pressures, sizes, configurations, installation requirements and limits of use. |
Installation Instructions FL46727_R1_II_DRU047-A SS 2026-08-07.pdf Verified By: Hermes F. Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL46727_R1_AE_PER10892 SS 2026-08-07.pdf Created by Independent Third Party: Yes |