| 16892.1 |
Amarr Classica 1000, 2000 (Model 500) |
IRC-5318-130-24-I Thru 18'-0" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.1/-28.4 Other: Glazing not available |
Installation Instructions FL16892_R5_II_IRC-5318-130-24-I Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_IRC-5318-130-24-I Evaluation Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 16892.2 |
Amarr Classica 3000 (Model 3000) |
IRC-3316-120-24 Thru 16'-0" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +21.8/-24.8 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL16892_R5_II_IRC-3316-120-24 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_IRC-3316-120-24 Evaluation Report 7-16 FL.pdf FL16892_R5_AE_IRC-3316-120-24 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 16892.3 |
Amarr Classica 3000 (Model 3000) |
IRC-3316-130-24 Thru 16'-0" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.3/-28.8 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL16892_R5_II_IRC-3316-130-24 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_IRC-3316-130-24 Evaluation Report 7-16 FL.pdf FL16892_R5_AE_IRC-3316-130-24 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 16892.4 |
Amarr Heritage 3000 (Model 1200);Amarr Oak Summit 3000 (Model 1200) |
IRC-1216-175-26-G Thru 16'-0" wide |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +48.0/-52.0 Other: Long Panel Glazing is 1/4" Polycarbonate with aluminum frame |
Installation Instructions FL16892_R5_II_IRC-1216-175-26-G Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_c5463.01-106-18-r1.pdf FL16892_R5_AE_IRC-1216-175-26-G Evaluation Report 7-16 FL.pdf FL16892_R5_AE_NOA 18-0918.06 compliance to 2020 FBC.pdf FL16892_R5_AE_TUFFAK Polycarbonate NOA 18-0918.06.pdf Created by Independent Third Party: Yes |
|
|
| 16892.5 |
Amarr Stratford 3000 (Model 1500);Amarr Heritage 3000 (Model 1200);Amarr Oak Summit 3000 (Model 1550) |
IRC-1518-120-24 Thru 18'-0" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +21.6/-24.5 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL16892_R5_II_IRC-1518-120-24 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_IRC-1518-120-24 Evaluation Report 7-16 FL.pdf FL16892_R5_AE_IRC-1518-120-24 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 16892.6 |
Amarr Stratford 3000 (Model 1500);Amarr Heritage 3000 (Model 1200);Amarr Oak Summit 3000 (Model 1550) |
IRC-1518-130-24 Thru 18'-0" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.4/-28.7 Other: Glazing is not available in wind borne debris regions |
Installation Instructions FL16892_R5_II_IRC-1518-130-24 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_IRC-1518-130-24 Evaluation Report 7-16 FL.pdf FL16892_R5_AE_IRC-1518-130-24 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 16892.7 |
Model 2700 (Amarr 2742);Model 2720 (Amarr 2042) |
IBC-2718-130-24-I Thru 18'-2" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.1/-28.4 Other: Glazing not available |
Installation Instructions FL16892_R5_II_IBC-2718-130-24-I Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL16892_R5_AE_IBC-2718-130-24-I Evaluation Report 7-16 FL.pdf FL16892_R5_AE_IBC-2718-130-24-I Report 7-16 FL.pdf Created by Independent Third Party: Yes |