Product Approval Menu > Application Detail
 
FL # FL9443-R5
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Union Corrugating
Address/Phone/Email 701 S. King Street
Fayetteville, NC 28301
(910) 483-2725
flvalidation@yahoo.com
 
Authorized Signature Jason Thorton
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report LOCKE BOWDEN
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Hermes F. Norero, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL9443_R5_COI_FL 9443 UNION CORRUGATING SSS.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1001995
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 04/20/2021
Date Validated 04/21/2021
Date Pending FBC Approval 05/07/2021
Date Approved 08/10/2021
 
Summary of Products
FL # Model, Number or Name Description
9443.1 1.5 Snap Lock Standing Seam 24 Ga. 16" 1.5 Snap Lock over plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0PSF
 Other: -116.0 PSF @ 6" O.C. Clip Spacing. -86.0 PSF @ 24" O.C. Clip Spacing. -108.5 PSF @ 12" O.C. Clip Spacing. Install per manufacturers details. See FBC 2020 for Underlayments. For use in HVHZ Zones.
Installation Instructions
 FL9443_R5_II_FL 9443 UNION CORRUGATING SSS.pdf
 Verified By: Locke Bowden, P.E. 49704