| 31384.1 |
Series 11000 High Impact Sliding Glass Door |
Sliding Door system made of laminated and insulated impact resistant glass retained by aluminum profile frame, wet glazed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-120 Other: Large & Small Missile Impact Resistant, see General Notes 1 thru 5 on Sheet 1 of Installation Drwg No. 20-229. ASD Pressure rating shown is a maximum, see schedule on Sheet 4 of Installation Drwg No. 20-229 for limitations on ASD pressure ratings. |
Installation Instructions FL31384_R1_II_2020.10.07 - 11000 High Impact SGD - DWG20-229 - Installation Drawings 2020.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL31384_R1_AE_11000 High Impact SGD - 20-229 - Evaluation Report SS.pdf Created by Independent Third Party: Yes |
|
|
| 31384.2 |
Series LAZH 1300 High Impact Reinforced Sliding Glass Door – Small Missile Impact / High Loads |
Sliding Door system made of laminated and insulated impact resistant glass retained by aluminum profile frame, wet glazed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-137 Other: Small Missile Impact Resistant, see General Notes 1 thru 5 on Sheet 1 of Installation Drwg No. 20-228. ASD Pressure rating shown is a maximum, see schedules on Sheets 3A, 22, 27A, & 46 of Installation Drwg No. 20-228 for limitations on ASD pressure ratings. |
Installation Instructions FL31384_R1_II_LAZH 1300 Reinforced SGD - DWG20-228 - Installation Drawings 2020.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL31384_R1_AE_LAZH 1300 Reinforced SGD - 20-228 - Evaluation Report SS.pdf Created by Independent Third Party: Yes |