| 31311.1 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
953mm x 1905mm (37.5" x 75") Window w/ Push-Out Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_411-H-1411.05.pdf Quality Assurance Contract Expiration Date 02/07/2030 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.2 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
899mm x 1194mm (35" x 47") Window w/ Side Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_Pella411CCL 905-22 23.pdf Quality Assurance Contract Expiration Date 08/18/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren Schaefer (PE) 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.3 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
1219mm x 2743mm (48" x 108") Window w/ Side Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glass shall conform to the current ASTM E1300 standard |
Certification Agency Certificate FL31311_R6_C_CAC_Pella411-905-27CCL.pdf Quality Assurance Contract Expiration Date 09/17/2030 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren Schaefer (PE) 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.4 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
889 x 1854 mm (35 x 73 in) Window w/ Side Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_411-H-905.19.pdf Quality Assurance Contract Expiration Date 08/18/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.5 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
889 x 1854 mm (35 x 73 in) Window w/ Center Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_411-H-905.09.pdf Quality Assurance Contract Expiration Date 08/02/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.6 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
889 x 2438 mm (35 x 96 in) Window w/ Side Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_411-H-905.13.pdf Quality Assurance Contract Expiration Date 06/14/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.7 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
889 x 2438 mm (35 x 96 in) Window w/ Center Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_411-H-905.11.pdf Quality Assurance Contract Expiration Date 06/11/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.8 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
1041 x 1956 mm (41 x 77 in) Window w/ Side Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_411-H-905.17.pdf Quality Assurance Contract Expiration Date 05/22/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |
|
|
| 31311.9 |
Pella/Architect Non-Impact Clad Wood Rectangular Vent Casement Windows |
762mm x 1854mm (30" x 73") Window w/ Side Pivot Hardware |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass shall conform to to the current ASTM E1300 standard. |
Certification Agency Certificate FL31311_R6_C_CAC_Pella411CCL 905-20 21.pdf Quality Assurance Contract Expiration Date 08/18/2028 Installation Instructions FL31311_R6_II_1604.pdf FL31311_R6_II_Anchor requirements in saltwater coastline areas.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL31311_R6_AE_1604.pdf Created by Independent Third Party: Yes |