| 9284.1 |
26 Ga. PBR Roof Panel |
26 Ga. PBR Roof Panel over open framing Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +50.0PSF/-40.0PSF Other: +50.0 psf @ 5'-0" o.c. -40.0 psf @ 5'-0" o.c. The panel is a thru-fastened structural roof panel installed over open framing. See manufacturer for additional installation detail drawings. Limitations Non-HVHZ. Engineer must evaluate the panel attachment to substrate for fastener pullout/pullover per AISI Specifications. Install per manufaturer erection details. The use of this panel for shear roof application is outside the scope of this product approval. |
Installation Instructions FL9284_R6_II_FL 9284 BAKER METAL ROOF DECK READY W DETAILS-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL9284_R6_AE_FL 9284 BAKER METAL ROOF DECK READY W DETAILS-ss.pdf Created by Independent Third Party: Yes |