| 30780.1 |
01: 145SL AllSeam 1.5" SnapLok 032 Aluminum |
145SL AllSeam 1.5" SnapLok panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: 161 psf with continuous clip and fasteners @ 6" oc, 131 psf with clips @ 12" oc, 92.25 psf with clips at 18" oc |
Installation Instructions FL30780_R5_II_32Al_145SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_32Al_145SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 30780.2 |
02: 145SL AllSeam 1.5" SnapLok 26ga |
145SL AllSeam 1.5" SnapLok panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: 176 psf with continuous clip and fasteners @ 6" oc, 116 psf with clips @ 12" oc, 64.75 psf with clips at 18" oc |
Installation Instructions FL30780_R5_II_26ga_145SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_26ga_145SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 30780.3 |
03: 155SL AllSeam 1.5" SnapLok 26ga |
155SL AllSeam 1.5" SnapLok panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-128.5 Other: 128.5 psf with clips at 12" oc |
Installation Instructions FL30780_R5_II_26ga_155SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_26ga_155SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 30780.4 |
04: 155SL AllSeam 1.5" SnapLok 032 Aluminum |
155SL AllSeam 1.5" SnapLok panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: 176 psf with clips @ 12" oc, 164.75 psf with clips @ 18" oc |
Installation Instructions FL30780_R5_II_32Al_155SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_32Al_155SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 30780.5 |
05: 175SL AllSeam 1.75" SnapLok 032 Aluminum |
175SL AllSeam 1.75" SnapLok panel from nominal 0.032" aluminum or thicker on 22ga(min) B deck or similar |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: 153.5psf with clips @ 10" oc, 123.5psf with clips @ 17" oc |
Installation Instructions FL30780_R5_II_32Al_175SL_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_32Al_175SL_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 30780.6 |
06: 175SL AllSeam 1.75" SnapLok 24ga |
175SL AllSeam 1.75" SnapLok panel from 24ga(min) on 22ga(min) B deck or similar |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: 161psf with clips @ 10" oc, 131psf with clips @ 17" |
Installation Instructions FL30780_R5_II_24ga_175SL_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_24ga_175SL_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 30780.7 |
07: 175SL AllSeam 1.75" SnapLok 24ga |
175SL AllSeam 1.75" SnapLok panel from 24ga(min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-243.5 Other: 243.5psf with clips @ 8" oc, 166psf with clips @ 16" oc |
Installation Instructions FL30780_R5_II_24ga_175SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_24ga_175SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 30780.8 |
08: 175SL AllSeam 1.75" SnapLok 032 Aluminum |
175SL AllSeam 1.75" SnapLok panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-228.5 Other: 228.5psf with clips @ 9" oc, 168.5psf with clips @ 19" oc |
Installation Instructions FL30780_R5_II_32Al_175SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_32Al_175SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 30780.9 |
09: 175SL AllSeam 1.75" SnapLok 24ga |
175SL AllSeam 1.75" SnapLok panel from 24ga(min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-243.5 Other: 243.5psf with clips @ 8" oc, 176psf with clips @ 16" oc |
Installation Instructions FL30780_R5_II_24ga_175SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_24ga_175SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 30780.10 |
10: 175SL AllSeam 1.75" SnapLok 032 Aluminum |
175SL AllSeam 1.75" SnapLok panel from 24ga(min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-191 Other: 191psf with clips @ 8" oc, 146psf with clips @ 16" oc |
Installation Instructions FL30780_R5_II_32Al_175SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_32Al_175SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 30780.11 |
11: 175SL AllSeam 1.75" SnapLok 7mm Zinc |
175SL AllSeam 1.75" SnapLok panel from 7mm Zinc (nom, min) on 17/32" (min) OSB, plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See report for details |
Installation Instructions FL30780_R5_II_Zn_175SL_OSB im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_Zn_175SL_OSB im.pdf Created by Independent Third Party: Yes |
|
|
| 30780.12 |
12: 175SL AllSeam 1.75" SnapLok 032 Aluminum |
175SL AllSeam 1.75" SnapLok panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: See report for details |
Installation Instructions FL30780_R5_II_32Al_175SL_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_32Al_175SL_plywood im.pdf Created by Independent Third Party: Yes |
|
|
| 30780.13 |
13: 175SL AllSeam 1.75" SnapLok 26ga |
175SL AllSeam 1.75" SnapLok panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See report for details |
Installation Instructions FL30780_R5_II_26ga_175SL_plywood_im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_26ga_175SL_plywood_im.pdf Created by Independent Third Party: Yes |
|
|
| 30780.14 |
14: 145SL AllSeam 1.5" SnapLok 26ga |
145SL AllSeam 1.5" SnapLok panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See report for details |
Installation Instructions FL30780_R5_II_26ga_145SL_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30780_R5_AE_26ga_145SL_plywood im.pdf Created by Independent Third Party: Yes |