| 21431.1 |
H3 2.0 Awning |
H3 2.0 Awning 2-Wide 95"x36" (48"x36" individual frame size) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-65 Other: Qualifies individual and 2-wide units with maximum individual frame size of 48"x36"; Masonry clip at head and sill of mull post; Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL21431_R4_C_CAC_CCL 436-H-659.22.pdf Quality Assurance Contract Expiration Date 10/05/2027 Installation Instructions FL21431_R4_II_H3 2 0 Awning OP 2-WIDE 95x36 CCL 436-H-659_22 ESP023331P-1999.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 21431.2 |
H3 2.0 Awning |
H3 2.0 Awning 3-Wide 120"x48" (40"x48" individual unit size)(Standard) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Qualifies individual to 3-wide unit with maximum individual frame size of 40"x48"; Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL21431_R4_C_CAC_CCL 436-H-659.16.pdf Quality Assurance Contract Expiration Date 01/26/2028 Installation Instructions FL21431_R4_II_H3 2 0 Awning OP 3-WIDE 120x48 CCL 436-H-659.16.19 ESP023456P-2017.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 21431.3 |
H3 2.0 Awning |
H3 2.0 Awning 3-Wide 120"x48" (40"x48" individual unit size)(HP) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-65 Other: Qualifies individual to 3-wide unit with maximum individual frame size of 40"x48"; Masonry clip at head and sill of each mull post; Complies with ASTM E1300 requirements.
When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL21431_R4_C_CAC_CCL 436-H-659.19.pdf Quality Assurance Contract Expiration Date 01/26/2028 Installation Instructions FL21431_R4_II_H3 2 0 Awning OP 3-WIDE 120x48 CCL 436-H-659.16.19 ESP023456P-2017.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |