| 21465.1 |
5120 / 514X /9100 /940X / 960X #0610 |
9'-0" Max width x 10'-0" Max Height. Max section height 24". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26.90/-30.80 Other: |
Installation Instructions FL21465_R3_II_0610-360633-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.2 |
5120 / 514X /9100 /940X / 960X #0611 |
16"-0" Max width x 10'-0" Max Height. Max section height 24". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 Other: |
Installation Instructions FL21465_R3_II_0611-360634-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.3 |
5120 / 514X /9100 /940X / 960X #0612 |
18"-0" Max width x 10'-0" Max Height. Max section height 24". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 Other: |
Installation Instructions FL21465_R3_II_0612-360635-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.4 |
5120 / 514X /9100 /940X / 960X #0613 |
18"-0" Max width x 8'-0" Max Height. Max section height 24". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30.00/-33.50 Other: |
Installation Instructions FL21465_R3_II_0613-360636-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.5 |
5120 / 9100 / 9605 #0240 |
9'-0" Max width x 8'-9" Max Height. Max section height 21". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26.90/-30.80 Other: |
Installation Instructions FL21465_R3_II_0240-360629-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.6 |
5120 / 9100 / 9605 #0241 |
16'-0" Max width x 8'-9" Max Height. Max section height 21". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 Other: |
Installation Instructions FL21465_R3_II_0241-360630-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.7 |
5120 / 9100 / 9605 #0242 |
16'-0" Max width x 8'-9" Max Height. Max section height 21". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.90/-28.80 Other: |
Installation Instructions FL21465_R3_II_0242-360631-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 21465.8 |
5120 / 9100 / 9605 #0243 |
18'-0" Max width x 8'-9" Max Height. Max section height 21". Glazing available in top or intermediate sections. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.40/-13.80 Other: |
Installation Instructions FL21465_R3_II_0243-360632-P00_s.pdf FL21465_R3_II_JambConnectionSupplement-WD-363342-P01_s.pdf FL21465_R3_II_TrackSupplement-WD-307494-P12_s.pdf Verified By: John E. Scates PE-51717 Created by Independent Third Party: Yes Evaluation Reports FL21465_R3_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |