Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL8954-R6
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments Q.A. Called into question on 11/18/25 m.c.
Archived
 
Product Manufacturer Metal Building Supplies, LLC
Address/Phone/Email 800 E. Donegan Ave
Kissimmee, FL 34744
(407) 935-9714
flvalidation@yahoo.com
 
Authorized Signature Scott Prossen
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 03/18/2034
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL8954_R6_COI_SS CERTIFICATE OF INDEPENDENCE.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
FM 44711992
TAS 1252003
TAS 2011994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/01/2023
Date Validated 09/05/2023
Date Pending FBC Approval 09/14/2023
Date Approved 12/12/2023
 
Summary of Products
FL # Model, Number or Name Description
8954.1 PBR Roof Panel 24 Ga. PBR Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-60.0PSF
 Other: -60.0 psf @ 5'-0" o.c. -150.0 psf @ 2'-0" o.c. The panel is a thru-fastened structural roof panel installed over open framing in accordance with the specified loads for windward/leeward wind pressures. Design Engineer must evaluate panel attachment to substrate for fastener pullout/pullover per AISI Specifications. Install per manufacturer erection details and RAS 133. The use of this panel for shear roof application is outside the scope of this product approval. HVHZ
Installation Instructions
 FL8954_R6_II_SS FL 8954 ALL REPORTS AND INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8954_R6_AE_SS FL 8954 ALL REPORTS AND INSTALL DETAILS.pdf
 Created by Independent Third Party: Yes
8954.2 PBR Roof Panel 26 Ga. PBR Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +60.0psf/-47.5psf
 Other: +60.0psf / -47.5 psf @ 5'-0" o.c. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL8954_R6_II_SS FL 8954 ALL REPORTS AND INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL8954_R6_AE_SS FL 8954 ALL REPORTS AND INSTALL DETAILS.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824