| 15475.1 |
Custom Clad Wood |
Casement 36" x 72" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-75 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Installation Instructions FL15475_R8_II_JW027_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15475_R8_AE_PER2861.pdf Created by Independent Third Party: Yes |
|
|
| 15475.2 |
Custom Clad Wood |
Casement 32" x 54" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-90 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Installation Instructions FL15475_R8_II_JW027_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15475_R8_AE_PER2861.pdf Created by Independent Third Party: Yes |
|
|
| 15475.3 |
Custom Clad Wood |
Casement Insash 36" x 72" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-75 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Installation Instructions FL15475_R8_II_JW028_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15475_R8_AE_PER2862.pdf Created by Independent Third Party: Yes |
|
|
| 15475.4 |
Custom Clad Wood |
Casement Insash 32" x 54" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-90 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Installation Instructions FL15475_R8_II_JW028_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15475_R8_AE_PER2862.pdf Created by Independent Third Party: Yes |
|
|
| 15475.5 |
Custom Clad Wood |
Casement 36" x 72" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Installation Instructions FL15475_R8_II_FL16899_R4_II_JW027 SS 2023-04-04.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL15475_R8_AE_FL16899_R4_AE_PER8311 SS 2023-04-04.pdf Created by Independent Third Party: Yes |