FL # FL32090-R3
Application Type Revision
Code Version 2026
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Sierra Pacific Windows
Address/Phone/Email 11605 Reading Road
PO Box 8489
Red Bluff, CA 96080
(715) 748-1716
jgouza@spi-ind.com
 
Authorized Signature Gouza Jessica
jgouza@spi-ind.com
 
Technical Representative Jessica Gouza
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1716
jgouza@spi-ind.com
 
Quality Assurance Representative Jessica Gouza
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1716
jgouza@spi-ind.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E1886-13a2013
ASTM E1996-172017
ASTM/WDMA/CSA 101/I.S.2/A440-112011
ASTM/WDMA/CSA 101/I.S.2/A440-172017
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL32090_R3_Equiv_2019-01 Tech Bulletin ASTM E1996-E1886 Equivalency.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/14/2026
Date Validated 07/20/2026
Date Pending FBC Approval
Date Approved 07/21/2026
 
Summary of Products
FL # Model, Number or Name Description
32090.1 FeelSafe H3 Fixed Casement FeelSafe H3 Fixed Casement 71.5"x 71.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Glass- IG Lami (3.1 mm AN/.090" SGP/3.1mm AN-11.5mm spacer-5.7mm Temp interior lite); Complies with E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-660.110-112.pdf
Quality Assurance Contract Expiration Date
 02/24/2030
Installation Instructions
 FL32090_R3_II_H3 2.0 FeelSafe CA Pic 72x72 CCL436-H-660_110-112 ESP032885P_2530.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.2 Westchester Clad Picture Westchester Clad Picture 47.5"x 95.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-690.26-.27.pdf
Quality Assurance Contract Expiration Date
 01/21/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Pic 48x96 CCL436-H-690_26-30 ESP032826P-2529_15.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.3 Westchester Clad Picture Westchester Clad Picture 72"x 108"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with ASTM E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-690.00-.01.pdf
Quality Assurance Contract Expiration Date
 02/12/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Pic 72x108 CCL436-H-690_00-04 ESP032826P-2529_5.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.4 Westchester Clad Picture Westchester Clad Picture 83.5"x 71.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other: Complies with E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-690.10-.11.pdf
Quality Assurance Contract Expiration Date
 01/21/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Pic 84x72 CCL435-H-690_10-14 ESP032826P-2529_14.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.5 Westchester Clad Picture Westchester Clad Picture 83.5"x 95.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-690.05-.06.pdf
Quality Assurance Contract Expiration Date
 01/21/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Pic 84x96 CCL435-H-690_05-09 ESP032826P-2529_6a.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.6 Westchester Clad Transom Westchester Clad Transom 95.5"x 47.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-690.16-17.pdf
Quality Assurance Contract Expiration Date
 04/07/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Transom 96x48 CCL436-H-690_16-20 ESP032826P-2529_9.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.7 Westchester Clad Transom Westchester Clad Transom 71.5"x 83.5"; Thru Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with ASTM E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-690.31-.32.pdf
Quality Assurance Contract Expiration Date
 04/07/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Transom 72x84 CCL436-H-690.31-.35 ESP33930P-2570_2 Thru-Frame.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
32090.8 Westchester Clad Transom Westchester Clad Transom 72"x 84"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with E1300 requirements. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026.
Certification Agency Certificate
 FL32090_R3_C_CAC_436-H-690.21-.22.pdf
Quality Assurance Contract Expiration Date
 04/07/2030
Installation Instructions
 FL32090_R3_II_Westchester DH Transom 72x84 CCL436-H-690_21-25 ESP032826P-2529_8.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex