| 33812.1 |
Series “NOVA” Single Hung Window |
Series “NOVA” Single Hung Window (O/X) - 52" x 72" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: |
Certification Agency Certificate FL33812_R9_C_CAC_NI015471-R2.pdf Quality Assurance Contract Expiration Date 08/31/2028 Installation Instructions FL33812_R9_II_ECOGLASS014_Rev0_EcoGlass_Series NOVA SH_ss.pdf Verified By: Robert J. Amoruso, PE FL PE 49752 Created by Independent Third Party: Yes Evaluation Reports FL33812_R9_AE_PER_ACE-1064_Rev1_Eco Glass_Series NOVA SH_ss.pdf Created by Independent Third Party: Yes |
|
|
| 33812.2 |
Series S-3450 Single Hung Window |
Series S-3450 PVC Single Hung Window, Impact, HVHZ, 52" x 72" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL33812_R9_C_CAC_NI016627 S3450 SH.pdf Quality Assurance Contract Expiration Date 12/31/2028 Installation Instructions FL33812_R9_II_ECOGLASS018-HVHZ_Rev0_EcoGlass_S-3450 PVC SH_ss.pdf Verified By: Robert J. Amoruso, FL PE PE License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL33812_R9_AE_PER-ACE-1122_Rev0_ACE-2025-303_SH_S3450_Ecoglass_ss.pdf Created by Independent Third Party: Yes |
|
|
| 33812.3 |
Series S-3770 Single Hung Window |
Series S-3770 Single Hung Window (O/X) - PVC/Vinyl - 48" x 108" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: |
Certification Agency Certificate FL33812_R9_C_CAC_NI014990-R2.pdf Quality Assurance Contract Expiration Date 09/30/2028 Installation Instructions FL33812_R9_II_ECOGLASS003_Rev0_EcoGlass_Series3770 SH_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL33812_R9_AE_PER_ACE-1030_Rev2_Eco Glass_Series S-3770 SH_ss.pdf Created by Independent Third Party: Yes |
|
|
| 33812.4 |
Series S-3775 Single Hung Window |
Series S-3775 Single Hung Window (O/X) - PVC/Vinyl - 52" x 72" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: |
Certification Agency Certificate FL33812_R9_C_CAC_NI015143-R2.pdf Quality Assurance Contract Expiration Date 09/30/2028 Installation Instructions FL33812_R9_II_ECOGLASS012_Rev0_EcoGlass_Series3775 SH_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL33812_R9_AE_PER_ACE-1054_Rev1_Eco Glass_Series S-3775 SH_ss.pdf Created by Independent Third Party: Yes |