| 21580.1 |
1 - FLAMCO "Off-Ridge Roof Vent" |
Low profile, off-ridge roof vent for pitched roofs fabricated from 26 gauge, G-90 primed, galvanized steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-46 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment.
|
Installation Instructions FL21580_R5_II_1_OffRidgeRoofVent_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL21580_R5_AE_1_OffRidgeRoofVent_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 21580.2 |
2 - FLAMCO "Gooseneck Roof Vent" |
Gooseneck style roof vents for sloped shingle or tile roofs fabricated from 26 gauge, G-90 primed, galvanized steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-SeeTable Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL21580_R5_II_2_GooseneckRoofVent_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL21580_R5_AE_2_GooseneckRoofVent_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
|
| 21580.3 |
3 - FLAMCO "RV 10 Ridge Vent" |
Aluminum Ridge Vents for pitched roofs fabricated from 0.025” Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL21580_R5_II_3_RV10_RidgeVent_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL21580_R5_AE_3_RV10_RidgeVent_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 21580.4 |
4 (R5) - FLAMCO "Off-Ridge Roof Vent with Permanent Baffle" |
Low profile, off-ridge roof vent with permanent baffle for pitched roofs fabricated from 26 gauge, G-90 primed, galvanized steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-46 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL21580_R5_II_4_OM_ORVwBaffle_EVALREPORT.pdf Verified By: James L. Buckner, P.E. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL21580_R5_AE_4_OM_ORVwBaffle_EVALREPORT.pdf Created by Independent Third Party: Yes |