| 20821.1 |
Continuous Cleat Coping |
5 1/2" front face height, 4 1/2" back face height, 10" wide.
24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 229 psf and rated upward 397 psf |
Installation Instructions FL20821_R3_II_Continuous Cleat Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.2 |
Continuous Cleat Coping |
5 1/2" front face height, 4 1/2" back face height, 10" wide.
.040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 231 psf and rated upward 400 psf |
Installation Instructions FL20821_R3_II_Continuous Cleat Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.3 |
Continuous Cleat Coping |
5 1/2" front face height, 4 1/2" back face height, 24 wide.
.040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 98 psf and rated upward 170 psf |
Installation Instructions FL20821_R3_II_Continuous Cleat Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.4 |
Continuous Cleat Coping |
5 1/2" front face height, 4 1/2" rear face height, 24" wide.
.24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 90 psf and rated upward 157 psf |
Installation Instructions FL20821_R3_II_Continuous Cleat Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.5 |
Drip Edge Fascia |
7 3/4" face height, .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 243 psf |
Installation Instructions FL20821_R3_II_Drip Edge Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.6 |
Drip Edge Fascia |
7 3/4" face height, 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 230 psf |
Installation Instructions FL20821_R3_II_Drip Edge Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.7 |
Edge-Lok 2 Fascia |
11 3/4" face height, .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 50 psf |
Installation Instructions FL20821_R3_II_Edge Lok 2 Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.8 |
Edge-Lok 2 Fascia |
11 3/4" face height, 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 40 psf |
Installation Instructions FL20821_R3_II_Edge Lok 2 Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.9 |
Edge-Lok 3 Fascia |
11 3/4" face height, .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 133 psf |
Installation Instructions FL20821_R3_II_Edge Lok 3 - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.10 |
Edge-Lok 3 Fascia |
11 3/4" face height, 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 140 psf |
Installation Instructions FL20821_R3_II_Edge Lok 3 Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.11 |
Gravel Stop |
8 1/2" face height, .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 203 psf |
Installation Instructions FL20821_R3_II_Gravel Stop Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.12 |
Gravel Stop |
8 1/2" face height, 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 200 psf |
Installation Instructions FL20821_R3_II_Gravel Stop Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.13 |
Rapid-Lok Coping |
7 1/2 front face height, 5 1/2 back face height, 12 3/4" wide.
24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 60 psf and rated upward 103 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.14 |
Rapid-Lok Coping |
7 1/2: front face height, 5 1/2" back face height, 12 3 /4" wide.
.040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 67 psf and rated upward 117 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.15 |
Rapid-Lok Coping |
7 1/2" front face height, 5 1/2" back face heath, 32" wide. 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 25 psi and rated upward 43 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.16 |
Rapid-Lok Coping |
7 1/2" front face, 5 1/2" back face, 32" wide. .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 29 psf and rated upward 50 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Coping - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.17 |
Rapid-Lok Fascia |
5 1/2 face height, 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 593 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.18 |
Rapid-Lok Fascia |
11 1/2" face height, 24 ga. steel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 133 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |
|
|
| 20821.19 |
Rapid-Lok Fascia |
5 1/2" face height, .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 490 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.01-119-16-r1.pdf |
|
|
| 20821.20 |
Rapid-Lok Fascia |
11 1/2" face height, .040 aluminum |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Rated outward 167 psf |
Installation Instructions FL20821_R3_II_Rapid Lok Fascia - Design Drawing.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL20821_R3_TR_f1420.02-119-16-r0 (2).pdf |