| 5167.1 |
07-09, 07-10 and 07-20 |
Reflections 5500, PerfeXion Platinum, 6000EX Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 48x80 (+/-25 PSF), 56x84 (+/-25 PSF), 48x96 (+/-25 PSF), 53x76 (+/-50 PSF)-High TL, 36x63 (+/-50 PSF), 44x64 (+/-50 PSF), 47x71 (+/-50 PSF)-High TL, 37x84 (+/-60 PSF)-High TL, 37x76 (+65/-70 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_07-09 DH (10111) 44x63 PG50.pdf FL5167_R49_C_CAC_07-09 DH (10394) 36x63 PG50.pdf FL5167_R49_C_CAC_07-09 DH (10395) 48x80 PG25.pdf FL5167_R49_C_CAC_07-09 DH (10988) 56x84 PG25.pdf FL5167_R49_C_CAC_07-09 DH (10989) 37x84 PG60.pdf FL5167_R49_C_CAC_07-09 DH (11311) 47x71 PG50.pdf FL5167_R49_C_CAC_07-09 DH (11312) 37x76 PG65.pdf FL5167_R49_C_CAC_07-09 DH (13787) 53x76 PG50.pdf FL5167_R49_C_CAC_07-09-10-20 and 08-09-10-20 Waiver.pdf FL5167_R49_C_CAC_07-20 DH (21077) R-PG25.pdf FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf Quality Assurance Contract Expiration Date 04/23/2027 Installation Instructions FL5167_R49_II_IN0066-R14.pdf FL5167_R49_II_IN0067-R18 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0066-R14.pdf Created by Independent Third Party: Yes |
|
|
| 5167.2 |
07-09, 07-10 and 07-20 |
Reflections 5500, PerfeXion Platinum, 6000EX Vinyl Double Hung with Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 53x130 |
Certification Agency Certificate FL5167_R49_C_CAC_07-09 DH w Transom (10812).pdf FL5167_R49_C_CAC_07-09-10-20 and 08-09-10-20 Waiver.pdf FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf Quality Assurance Contract Expiration Date 04/19/2030 Installation Instructions FL5167_R49_II_IN0063-R13 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.3 |
07-09, 07-10 and 07-20 |
Reflections 5500, PerfeXion Platinum, 6000EX Vinyl Double Hung H-Mulled Triple |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 160x76, 126x76 |
Certification Agency Certificate FL5167_R49_C_CAC_07-09 DH Triple (10761) 106x76 PG50.pdf FL5167_R49_C_CAC_07-09 DH Triple (10802) 102x76 PG50.pdf FL5167_R49_C_CAC_07-09-10-20 and 08-09 -10 -20 Waiver.pdf FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf Quality Assurance Contract Expiration Date 04/19/2030 Installation Instructions FL5167_R49_II_IN0555-R3 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.4 |
07-09, 07-10 and 07-20 |
Reflections 5500, PerfeXion Platinum, 6000EX Vinyl Double Hung Triple with Transom Triple |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: 109x88 |
Certification Agency Certificate FL5167_R49_C_CAC_07-09 DH Triple wTransom (10779).pdf FL5167_R49_C_CAC_07-09-10-20 and 08-09-10-20 Waiver.pdf FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf Quality Assurance Contract Expiration Date 12/13/2031 Installation Instructions FL5167_R49_II_IN0556-R4 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.5 |
07-20 75-75 (Nailing Fin Installation) |
Reflections 5500, PerfeXion Platinum, 6000EX Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 56x84 (+/-25 PSF), 48X96 (+/-25 PSF), 52 x 71 (+/-35 PSF), 53x76 (+/-50 PSF) & 37x76 (+/-65 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_07-20 DH (21077) R-PG25.pdf FL5167_R49_C_CAC_07-20 DH (5044).pdf FL5167_R49_C_CAC_07-20 DH (5045).pdf FL5167_R49_C_CAC_07-20 DH (5046).pdf FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf FL5167_R49_C_CAC_75-75 DH (11078) 52x71 PG35.pdf Quality Assurance Contract Expiration Date 06/06/2027 Installation Instructions FL5167_R49_II_IN0129-R10.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.6 |
42-19 |
ProFinish Brickmould 600, PerfeXion BM 600, 4500 Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 52x71 (+/-35 PSF), 48x80 (+/-35 PSF), 36x63 (+/-50 PSF), 36x74 (+/-50 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_42-19 DH (5127).pdf FL5167_R49_C_CAC_42-19 DH (5128).pdf FL5167_R49_C_CAC_42-19 DH (5129).pdf FL5167_R49_C_CAC_42-19 DH(5301).pdf Quality Assurance Contract Expiration Date 09/14/2029 Installation Instructions FL5167_R49_II_IN0130-R7 1x.pdf FL5167_R49_II_IN0148 -R9 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0130-R7.pdf Created by Independent Third Party: Yes |
|
|
| 5167.7 |
42-19 |
ProFinish Brickmould 600, PerfeXion BM 600, 4500 Vinyl Double Hung Twin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 89x63 (+/-30 PSF), 97x80 (+/-30 PSF), 73x63 (+/-35), 73x76 (+/-50 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_42-19 DH Twin (5415).pdf FL5167_R49_C_CAC_42-19 DH Twin (5416).pdf FL5167_R49_C_CAC_42-19 DH Twin (5786).pdf FL5167_R49_C_CAC_42-19 DH Twin (5787).pdf Quality Assurance Contract Expiration Date 10/05/2029 Installation Instructions FL5167_R49_II_IN0150-R8 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.8 |
42-19 |
ProFinish Brickmould 600, PerfeXion BM 600, 4500 Vinyl Double Hung Triple |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: 109x74 |
Certification Agency Certificate FL5167_R49_C_CAC_42-19 DH Triple (5417).pdf Quality Assurance Contract Expiration Date 10/05/2029 Installation Instructions FL5167_R49_II_IN0151-R8 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.9 |
43-17 |
Profinish Contractor, PerfeXion Contractor Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 36x72 (+/-30 PSF), 48x80 (+/-30 PSF), 53x71 (+/-35 PSF), 44x63 (+/-35 PSF), 48x80 (+/-35 PSF), 36x63 (+/-45 PSF), 44x63 (+/-45 PSF), 26x76 (+/-50 PSF) & 36x74 (+/-50 PSF), 32x62 (+/-50 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_43-17 DH (10126) 44x63 PG45.pdf FL5167_R49_C_CAC_43-17 DH (10391) 48x80 PG35.pdf FL5167_R49_C_CAC_43-17 DH (10393) 36x74 PG50.pdf FL5167_R49_C_CAC_43-17 DH (10853) 36x63 PG45.pdf FL5167_R49_C_CAC_43-17 DH (5302).pdf FL5167_R49_C_CAC_43-17 DH (5303).pdf FL5167_R49_C_CAC_43-17 DH (9201) 36x72 PG30.pdf FL5167_R49_C_CAC_43-17 DH (9202) 32x62 PG50.pdf FL5167_R49_C_CAC_43-17 DH (9203) 36x74 PG50.pdf FL5167_R49_C_CAC_43-17 DH (Fin) (6664) 48x80 PG35.pdf FL5167_R49_C_CAC_43-17 DH (Fin) (6665) 26x76 PG50.pdf FL5167_R49_C_CAC_43-17 DH (Fin) (7600) 53X71 PG35.pdf Quality Assurance Contract Expiration Date 04/24/2027 Installation Instructions FL5167_R49_II_IN0096-R10 2x.pdf FL5167_R49_II_IN0254-R8 1x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0254-R8.pdf Created by Independent Third Party: Yes |
|
|
| 5167.10 |
43-17 |
Profinish Contractor, PerfeXion Contractor Vinyl Double Hung T-mulled Twin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 96x80 (+/-25 PSF), 89x63 (+/-30 PSF), 73x63 (+/-35 PSF) & 72x74 (+/-45 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_43-17 DH Twin (10820) 96x80 PG25.pdf FL5167_R49_C_CAC_43-17 DH Twin (10821) 72x74 PG45.pdf FL5167_R49_C_CAC_43-17 DH Twin (10861) 73x63 PG35.pdf FL5167_R49_C_CAC_43-17 DH Twin (9967) 89x63 PG30.pdf Quality Assurance Contract Expiration Date 04/22/2027 Installation Instructions FL5167_R49_II_IN0099-R7 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.11 |
43-35 (Two-Step Sill) |
6100, Asure, PerfeXion Silver Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 44x63 (+/-25 PSF), 46x84 (+/-25 PSF), 36x72 (+/-30 PSF), 48x80 (+/-35 PSF), 52x71 (+/-35 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_43-35 DH (8151) 46x84-PG25.pdf FL5167_R49_C_CAC_43-35 DH (8152) 36x72-PG30.pdf FL5167_R49_C_CAC_43-35 DH (8153) 44x63-PG25.pdf FL5167_R49_C_CAC_43-35 DH (8155) 48x80-PG35.pdf FL5167_R49_C_CAC_43-35 DH (8156) 52x71-PG35.pdf Quality Assurance Contract Expiration Date 01/24/2031 Installation Instructions FL5167_R49_II_IN0105-R5 2x.pdf FL5167_R49_II_IN0568-R5 1x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0568-R5.pdf Created by Independent Third Party: Yes |
|
|
| 5167.12 |
43-35 (Two-Step Sill) and 43-50 (Three-Step Sill) |
6100, Asure, PerfeXion Silver Vinyl Double Hung Twin with Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: 73x111 |
Certification Agency Certificate FL5167_R49_C_CAC_43-35 FX over Twin DH (8360).pdf FL5167_R49_C_CAC_43-35 FX over Twin DH (8361).pdf Quality Assurance Contract Expiration Date 01/24/2031 Installation Instructions FL5167_R49_II_IN0535-R4 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.13 |
43-40 and 43-45 |
Reflections 5050, Reflections 5300, 6100, PerfeXion Gold, 4000E Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 36x72 (+/-30 PSF), 52x71 (+/-35 PSF), 48x80 (+/-35 PSF), 36x63 (+/-45 PSF), 44x63 (+/-45 PSF), 44x63 (+/-35 PFS), 32x62 (+/-50 PSF), 36x74 (+/-50 PSF), 46x84 (+/-25) |
Certification Agency Certificate FL5167_R49_C_CAC_43-40 DH (10390) 32x62 PG50.pdf FL5167_R49_C_CAC_43-40 DH (10392) 44x63 PG35.pdf FL5167_R49_C_CAC_43-40 DH (12109) 46x84 R-PG25.pdf FL5167_R49_C_CAC_43-40 DH (12110) 44x63 R-PG45.pdf FL5167_R49_C_CAC_43-40 DH (9634) 36x63 PG45.pdf FL5167_R49_C_CAC_43-40 DH (9635) 36x72 PG30.pdf FL5167_R49_C_CAC_43-40 DH (9636) 52x71 PG35.pdf FL5167_R49_C_CAC_43-40 DH (9918) 48x80 PG35.pdf FL5167_R49_C_CAC_43-40 DH (9919) 36x74 PG50.pdf FL5167_R49_C_CAC_43-45 DH (9966) 52x71 PG35.pdf FL5167_R49_C_CAC_43-45 waiver to 43-40.pdf Quality Assurance Contract Expiration Date 11/04/2027 Installation Instructions FL5167_R49_II_IN0432b-R7 2x.pdf FL5167_R49_II_IN0434-R9 1x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0434-R9.pdf Created by Independent Third Party: Yes |
|
|
| 5167.14 |
43-50 (Three-Step Sill) |
6100, Asure, PerfeXion Silver Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 52x71 (+/-35 PSF), 36x63 (+/-45 PSF), 44x63 (+/-45 PSF), 32x62 (+/-50 PSF), 36x74 (+/-50 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_43-50 DH (8170)-PG45.pdf FL5167_R49_C_CAC_43-50 DH (8171)-PG45.pdf FL5167_R49_C_CAC_43-50 DH (8172)-PG50.pdf FL5167_R49_C_CAC_43-50 DH (8173)-PG50.pdf FL5167_R49_C_CAC_43-50 DH (8174)-PG35.pdf Quality Assurance Contract Expiration Date 01/25/2031 Installation Instructions FL5167_R49_II_IN0432-R9 2x.pdf FL5167_R49_II_IN0569-R5 1x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0569-R5.pdf Created by Independent Third Party: Yes |
|
|
| 5167.15 |
75-75, 75-09, 07-75, 07-09, 07-10 and 07-20 |
Reflections 5500, Generations, Impressions 9800, 6500, PerfeXion Platinum, 6000, 6000EX Vinyl Double Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: 48x80 (+/-25 PSF), 53x74 (+/-30 PSF), 48x80 (+/-35 PSF), 52x71 (+/-35 PSF), 53x80 (+/-40 PSF)-High TL, 36x63 (+/-50 PSF), 36x74 (+/-50 PSF), 36x72 (+/-55) |
Certification Agency Certificate FL5167_R49_C_CAC_07-75 DH (11945) 48x80 R-PG35.pdf FL5167_R49_C_CAC_07-75 DH (12084) 53x74 R-PG30.pdf FL5167_R49_C_CAC_07-75 DH (6544) 53x80 PG40.pdf FL5167_R49_C_CAC_75-75 DH (11047) 48X80 PG25.pdf FL5167_R49_C_CAC_75-75 DH (11048) 36x63 PG50.pdf FL5167_R49_C_CAC_75-75 DH (11078) 52x71 PG35.pdf FL5167_R49_C_CAC_75-75 DH (11339) 36x72 PG55.pdf FL5167_R49_C_CAC_75-75 DH (9540) 36x74 PG50.pdf FL5167_R49_C_CAC_ACP-05 SIM 07-75 DH HS PW frame 07-09.pdf FL5167_R49_C_CAC_ACP-05 SIM 75-75, 07-09, 07-75, 07-09, 75-10, 75-20 DH frame.pdf Quality Assurance Contract Expiration Date 06/06/2027 Installation Instructions FL5167_R49_II_IN0113-R15 2x.pdf FL5167_R49_II_IN0132-R13 1x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0132-R13.pdf Created by Independent Third Party: Yes |
|
|
| 5167.16 |
75-75, 75-09, 07-75, 07-09, 07-10 and 07-20 |
Reflections 5500, Generations, Impressions 9800, 6500, PerfeXion Platinum, 6000, 6000EX Double Hung H-Mulled Triple |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 109x74 (+/-50 PSF) |
Certification Agency Certificate FL5167_R49_C_CAC_07-09-10-20 and 08-09-10-20 Waiver.pdf FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf FL5167_R49_C_CAC_75-75 DH Triple (10801) PG50.pdf Quality Assurance Contract Expiration Date 09/13/2031 Installation Instructions FL5167_R49_II_IN0060-R9 2x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 5167.17 |
75-75, 75-09, 07-75, 07-09, 07-10 and 07-20 |
Reflections 5500, Generations, Impressions 9800, 6500, PerfeXion Platinum, 6000, 6000EX Vinyl Double Hung H-Mulled Twin with Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 73x111 *Glazing complies with ASTM E 1300-04. |
Certification Agency Certificate FL5167_R49_C_CAC_07-75 waiver to 07-09.pdf FL5167_R49_C_CAC_75-75 DH Twin w-Transom (10745).pdf Quality Assurance Contract Expiration Date 09/13/2031 Installation Instructions FL5167_R49_II_IN0062-R9 1x.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL5167_R49_AE_EvalReport-IN0062-R9.pdf Created by Independent Third Party: Yes |