| 8889.1 |
PBR Panel |
26 Ga. PBR Roof Panel 36" Wide over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +32.7 psf/-32.1 PSF Other: +32.7 /-32.1 psf allowable load for 26 ga with 12-12 fastener spacing at support spacing of 5'0" o.c. See evaluation report for additional pressure and uplift span load information. |
Installation Instructions FL8889_R4_II_FL8889_R0_II_Roof Details.pdf Verified By: Patrick Barrick PE 92998 Created by Independent Third Party: No Evaluation Reports FL8889_R4_AE_26 Ga PBR Roof Evaluation Report.pdf Created by Independent Third Party: Yes |
|
|
| 8889.2 |
PBR Panel |
24 Ga. PBR Roof Panel 36" Wide over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +51.6 PSF/-38.2 PSF Other: +51.6 / -38.2 psf allowable load for 24 gauge with 12-12 fastener spacing at support spacing of 5'-0" o.c. See evaluation report for additional pressure and uplift span load information. |
Installation Instructions FL8889_R4_II_FL8889_R0_II_Roof Details.pdf Verified By: Patrick Barrick 92998 Created by Independent Third Party: No Evaluation Reports FL8889_R4_AE_24 Ga PBR Roof Evaluation Report.pdf Created by Independent Third Party: Yes |