Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL48402
Application Type New
Code Version 2026
Application Status Approved
 
Comments 1st validation- 8.20.26 m.c. Was set to re-apply on 9/3/26. m.c.
Archived
 
Product Manufacturer American Steel Manufacturing, LLC
Address/Phone/Email 692 South Military Trail
Suite B
Deerfield Beach, FL 33442
(954) 419-9918   Ext 227
Ron@AmericanSteelWindows.com
 
Authorized Signature Ron Collins
Ron@AmericanSteelWindows.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Javad Ahmad
Florida License PE-70592
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 10/18/2034
Validated By Ammad Riaz, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL48402_R0_COI_Certificate_of_Independence_JA-PE1.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E283/E283M2019
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/20/2026
Date Validated 09/07/2026
Date Pending FBC Approval 09/15/2026
Date Approved 10/13/2026
 
Summary of Products
FL # Model, Number or Name Description
48402.1 Skylight System (L.M.I. & S.M.I.) Skylight System (Large and Small Missile Impact resistant) / Thermally Broken and Non-Thermally Broken
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Please see enclosed documents for product performance information, maximum sizes, anchorage details, installation requirements, and limits of use.
Installation Instructions
 FL48402_R0_II_SKYLIGHT_SYSTEM-JA-1829-25-SS.pdf
 Verified By: Javad Ahmad PE# 70592
 Created by Independent Third Party: Yes
Evaluation Reports
 FL48402_R0_AE_ASM-Skylight-PA_EVR1.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex