| 48471.1 |
1- "Series T3020" |
24 gauge steel T-Seam roof panel mechanically attached to Steel Deck with fixed panel clips & screws |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-TableA Other: Refer to Evaluation Report for Conditions and Limitations of Use. Refer to manufacturer's installation instructions as a supplemental guide. |
Installation Instructions FL48471_R0_II_1_T3020_24ga_SteelDeck_EVALREPORT_hz.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL48471_R0_AE_1_T3020_24ga_SteelDeck_EVALREPORT_hz.pdf Created by Independent Third Party: Yes |
|
|
| 48471.2 |
2- "Series T3020" |
0.040” Aluminum T-Seam roof panel mechanically attached to Steel Deck with fixed panel clips & screws. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-TableA Other: Refer to Evaluation Report for Conditions and Limitations of Use. Refer to manufacturer's installation instructions as a supplemental guide. |
Installation Instructions FL48471_R0_II_2_T3020_040Alum_SteelDeck_EVALREPORT_hz.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL48471_R0_AE_2_T3020_040Alum_SteelDeck_EVALREPORT_hz.pdf Created by Independent Third Party: Yes |