FL # FL10094-R7
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer BAKER METAL WORKS & SUPPLY, INC.
Address/Phone/Email 5846 Hwy 189
BAKER, FL 32531
(850) 537-2010
flvalidation@yahoo.com
 
Authorized Signature JASON NORTON
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/13/2027
Validated By Diane Marotta, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL10094_R7_COI_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
FM 44711992
TAS 1001995
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/23/2020
Date Validated 10/23/2020
Date Pending FBC Approval 01/08/2021
Date Approved 02/09/2021
Date Revised 10/15/2023
 
Summary of Products
FL # Model, Number or Name Description
10094.1 26 Ga. 3/4" Rib 26 Ga. 3/4" Rib Roof Panel over 1x4 No. 2 SYP Wood Purlins over APA Plywood.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-164.2psf
 Other: -106.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. Fastener spacing. -164.25 psf @ 9"-9"-9"-9" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details in compliance w/CURRENT FBC . For use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.2 26 Ga. 3/4" Rib 26 Ga. 3/4" Rib Roof Panel over APA Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-159.2psf
 Other: -71.75 psf @ 9"-9"-9"-9 fastener pattern @ 24" O.C. fastener spacing. -159.25 psf @ 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details in compliance w/CURRENT FBC . For use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.3 26 Ga. 5V Roof Panel 26 Ga. 5V Roof Panel over APA Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-156.5psf
 Other: -108.5 PSF @ 12" Fastener Spacing in panel rib. -156.5 PSF @ 6" Fastener Spacing in panel rib. Install per manufacturers details in compliance w/CURRENT FBC For use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.4 26 Ga. 5V Roof Panel 26 Ga. 5V Roof Panel over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0PSF
 Other: -56.0 psf at 12”-12” Fastener Pattern at 24” O.C. -101.0 psf at 9.5”-2”-9.5” Fastener Pattern at 24” O.C. -116.0 psf at 12”-12” Fastener Pattern at 12” O.C. in the flat of the panel. Install per manufacturers details in compliance w/CURRENT FBC . Not for use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.5 26 Ga. 5V Roof Panel 26 Ga. 5V Roof Panel over 1 x 4 No. 2 SYP Wood Purlins over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-146.0PSF
 Other: -71.0 psf at 12”-12” Fastener Pattern at 24” O.C. -146.0 psf at 9.5”-2”-9.5” Fastener Pattern at 24” O.C. in the flat of the panel. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.6 26 Ga. Corrugated 26 Ga. Corrugated Roof Panel over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0PSF
 Other: -63.5 psf at 10 ¾”- 10 ¾” Fastener Pattern at 24” O.C. -116.0 psf at 5 3/8”-5 3/8”-5 3/8”-5 3/8” Fastener Pattern at 24” O.C. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.7 26 Ga. Corrugated 26 Ga. Corrugated Roof Panel over 1 x 4 SYP Wood Purlins over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-131.0PSF
 Other: -93.5 psf at 10 ¾”- 10 ¾” Fastener Pattern at 24” O.C. -131.0 psf at 5 3/8”-5 3/8”-5 3/8”-5 3/8” Fastener Pattern at 24” O.C.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.8 26 Ga. PBR 26 Ga. PBR Roof Panel over 1x4 No. 2 SYP Wood Purlins over APA Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-151.7psf
 Other: -100.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. -151.75 psf @ 7"-5"-7"-5"-7"-5" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.9 26 Ga. PBR 26 Ga. PBR Roof Panel over APA Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-154.7psf
 Other: -60.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. -154.75 psf @ 7"-5"-7"-5"-7"-5" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.10 Min. 29 Ga. 3/4" Rib Min. 29 Ga. 3/4" Rib Roof Panel over 1x4 SYP Wood Purlins over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0psf
 Other: Type 1: -86.0 psf 9"-9"-9"-9" fastener pattern @ 24" o.c. Type 2: -116.0 psf 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 24" o.c. Install per manufacturer details. Not for use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.11 Min. 29 Ga. 3/4" Rib Min. 29 Ga. 3/4" Rib Roof Panel over 15/32" APA Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5psf
 Other: -71.0 psf 9"-9"-9"-9" fastener pattern @ 24" o.c. Type 2: -108.5 psf 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 24" o.c. Install per manufacturer details. Not for use in HVHZ Zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
10094.12 Tuff-Rib 26GA over Purlins Tuff-Rib 26GA over 2x6 SYP Wood Treated Purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-67.5
 Other: -52.5 psf 9"-9"-9"-9" fastener pattern @ 24" o.c. Type 2:-67.5 psf 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 24" o.c. Install per manufacturer details. Not for use in HVHZ zones.
Installation Instructions
 FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf
 Created by Independent Third Party: Yes
 