| 10094.1 |
26 Ga. 3/4" Rib |
26 Ga. 3/4" Rib Roof Panel over 1x4 No. 2 SYP Wood Purlins over APA Plywood. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.2psf Other: -106.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. Fastener spacing. -164.25 psf @ 9"-9"-9"-9" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details in compliance w/CURRENT FBC . For use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.2 |
26 Ga. 3/4" Rib |
26 Ga. 3/4" Rib Roof Panel over APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.2psf Other: -71.75 psf @ 9"-9"-9"-9 fastener pattern @ 24" O.C. fastener spacing. -159.25 psf @ 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details in compliance w/CURRENT FBC . For use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.3 |
26 Ga. 5V Roof Panel |
26 Ga. 5V Roof Panel over APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5psf Other: -108.5 PSF @ 12" Fastener Spacing in panel rib. -156.5 PSF @ 6" Fastener Spacing in panel rib. Install per manufacturers details in compliance w/CURRENT FBC For use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.4 |
26 Ga. 5V Roof Panel |
26 Ga. 5V Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -56.0 psf at 12”-12” Fastener Pattern at 24” O.C.
-101.0 psf at 9.5”-2”-9.5” Fastener Pattern at 24” O.C.
-116.0 psf at 12”-12” Fastener Pattern at 12” O.C. in the flat of the panel. Install per manufacturers details in compliance w/CURRENT FBC . Not for use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.5 |
26 Ga. 5V Roof Panel |
26 Ga. 5V Roof Panel over 1 x 4 No. 2 SYP Wood Purlins over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -71.0 psf at 12”-12” Fastener Pattern at 24” O.C. -146.0 psf at 9.5”-2”-9.5” Fastener Pattern at 24” O.C. in the flat of the panel. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.6 |
26 Ga. Corrugated |
26 Ga. Corrugated Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -63.5 psf at 10 ¾”- 10 ¾” Fastener Pattern at 24” O.C.
-116.0 psf at 5 3/8”-5 3/8”-5 3/8”-5 3/8” Fastener Pattern at 24” O.C. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.7 |
26 Ga. Corrugated |
26 Ga. Corrugated Roof Panel over 1 x 4 SYP Wood Purlins over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0PSF Other: -93.5 psf at 10 ¾”- 10 ¾” Fastener Pattern at 24” O.C.
-131.0 psf at 5 3/8”-5 3/8”-5 3/8”-5 3/8” Fastener Pattern at 24” O.C. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.8 |
26 Ga. PBR |
26 Ga. PBR Roof Panel over 1x4 No. 2 SYP Wood Purlins over APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7psf Other: -100.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. -151.75 psf @ 7"-5"-7"-5"-7"-5" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.9 |
26 Ga. PBR |
26 Ga. PBR Roof Panel over APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7psf Other: -60.5 psf @ 12"-12"-12" fastener pattern @ 24" o.c. fastener spacing. -154.75 psf @ 7"-5"-7"-5"-7"-5" fastener pattern @ 12" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.10 |
Min. 29 Ga. 3/4" Rib |
Min. 29 Ga. 3/4" Rib Roof Panel over 1x4 SYP Wood Purlins over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: Type 1: -86.0 psf 9"-9"-9"-9" fastener pattern @ 24" o.c. Type 2: -116.0 psf 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 24" o.c. Install per manufacturer details. Not for use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.11 |
Min. 29 Ga. 3/4" Rib |
Min. 29 Ga. 3/4" Rib Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -71.0 psf 9"-9"-9"-9" fastener pattern @ 24" o.c. Type 2: -108.5 psf 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 24" o.c. Install per manufacturer details. Not for use in HVHZ Zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |
|
|
| 10094.12 |
Tuff-Rib 26GA over Purlins |
Tuff-Rib 26GA over 2x6 SYP Wood Treated Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-67.5 Other: -52.5 psf 9"-9"-9"-9" fastener pattern @ 24" o.c. Type 2:-67.5 psf 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern @ 24" o.c. Install per manufacturer details. Not for use in HVHZ zones. |
Installation Instructions FL10094_R7_II_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10094_R7_AE_FL 10094 BAKER METAL METAL ROOFING-SS FINAL.pdf Created by Independent Third Party: Yes |