| 22039.1 |
Aluminum Clad Inswing 3-Wide Door 112x99 |
Aluminum Clad Inswing 3-Wide Door 112x99 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_Sierra 436-102.33-34 CCL.pdf Quality Assurance Contract Expiration Date 02/04/2026 Installation Instructions FL22039_R3_II_Clad Inswing Door 3Wide 112x99 CCL436-H-102_33-36 QCT26-7796_01.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 22039.2 |
Clad Bi-fold Outswing |
Clad Bi-fold Outswing 5-Panel 183"x100" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_Sierra 429-555.14 CCL.pdf Quality Assurance Contract Expiration Date 03/25/2035 Installation Instructions FL22039_R3_II_Outswing Bi-Fold Door 5 panel 183 x100 CCL436-H-555.14-16 S5091.01-901-47-R0.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 22039.3 |
Clad Inswing Patio Door |
Clad Inswing Patio Door 71"x120" (Handle Activated Shoot Bolt) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-35 Other: Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_436-H-102.22 CCL (1).pdf Quality Assurance Contract Expiration Date 01/23/2027 Installation Instructions FL22039_R3_II_ES CLAD Inswing Door 2W 71x120 -Handle Activated shoot bolts- CCL 436-H-102-22 ESP024430P-2087_2.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 22039.4 |
Clad Inswing Patio Door |
Clad Inswing Patio Door 71"x120" (Manual Activated Shoot Bolt) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Requires manual activated shoot bolt;Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_436-H-102.19 CCL.pdf Quality Assurance Contract Expiration Date 01/23/2027 Installation Instructions FL22039_R3_II_ES CLAD Inswing Door 2W 71x120 -manual shoot bolts- CCL 436-H-102-19 ESP024430P-2087_1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 22039.5 |
Clad Outswing Door |
Clad Outswing Patio Door 76"x120" (Manual Activated Shoot Bolt) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Requires manual activated shoot bolt;Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_436-H-611.52 CCL.pdf Quality Assurance Contract Expiration Date 01/25/2027 Installation Instructions FL22039_R3_II_ES CLAD Outswing Door 2W 76x120 -Manual Activated shoot bolts- CCL 436-H-611-52 ESP024430P-2087.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 22039.6 |
Clad Outswing Patio Door |
Clad Outswing Patio Door 76"x120" (Handle Activated Shoot Bolt) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_436-H-611.49 CCL.pdf Quality Assurance Contract Expiration Date 01/25/2027 Installation Instructions FL22039_R3_II_ES CLAD Outswing Door 2W 76x120 -Handle Activated shoot bolts- CCL 436-H-611-49 ESP024430P-2087_3.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 22039.7 |
Clad Outswing Patio Door |
Clad Outswing Patio Door 88"x99" (HP) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: Hoppe 5-point hardware w/manual lever shoot bolt; Panel Reinforcement; Stainless steel sill strike plate; Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL22039_R3_C_CAC_436-H-611.55 CCL.pdf Quality Assurance Contract Expiration Date 02/07/2027 Installation Instructions FL22039_R3_II_ES CLAD Outswing Door 2W 88x99 -Manual Activated shoot bolts- CCL 436-H-611_55 ESP024671P-2108.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |