Product Approval Menu > Application Detail
 
FL # FL37207-R1
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Marvin
Address/Phone/Email Hwy 11 West
Warroad, MN 56763
(218) 386-1430   Ext 2143
cherylf@marvin.com
 
Authorized Signature Chelsie Horner
ChelsieH@marvin.com
 
Technical Representative Cheryl Fish
Address/Phone/Email PO Box 100
Warroad, MN 56763
(800) 346-5044   Ext 2143
cherylf@marvin.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Double Hung
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
101/I.S.2/A4402011
AAMA 4502010
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/20/2023
Date Validated 12/22/2023
Date Pending FBC Approval
Date Approved 01/01/2024
Date Revised 09/14/2026
 
Summary of Products
FL # Model, Number or Name Description
37207.1 UDH - G2 4032 2W Combination Assembly Ultimate Double Hung - Generation 2 mulled to Clad Ultimate Double Hung - Generation 2 2W Combination Assembly 407-H-1127
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Max Size of Mulled Assembly: 2299mm x 1816mm (90 1/2" x 71 1/2"), Tributary Width 1149mm Span 1816mm ; Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL37207_R1_C_CAC_UDH G2 CCL 1127.28.29.pdf
Quality Assurance Contract Expiration Date
 03/29/2026
Installation Instructions
 FL37207_R1_II_94934.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
37207.2 UDHT - G2 2W over UDH - G2 2W Vertical Mull (3/8" MRF) 2W2H Ultimate Double Hung Transom - Generation 2 2W over Ultimate Double Hung - Generation 2 2W, Vertical Mull (3/8" MRF) 2W2H 407-H-1127
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-65
 Other: Max Size Mulled Assembly: 2308mm x 2113mm (90 7/8" x 83 3/16") ;Operator & Transom Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL37207_R1_C_CAC_UDHT G2 CCL 1127.26.27.pdf
Quality Assurance Contract Expiration Date
 04/29/2026
Installation Instructions
 FL37207_R1_II_95061.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
37207.3 UDHT - G2 4020 2W over 2W UDH - G2 4020 Vertical Mull (1" LVL) 2W2H Ultimate Double Hung Transom - Generation 2 2W over Ultimate Double Hung - Generation 2 2W, Vertical Mull (1" LVL) 2W2H 407-H-1127
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Max Size of Mulled Assembly: 2324mm x 1910mm (91 1/2" x 75 3/16") ;1905mm span x 1160mm trib width ( 75" span x 45-3/4" Trib Width); Operator & Transom Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL37207_R1_C_CAC_UDHT G2 CCL 1127.24.25.pdf
Quality Assurance Contract Expiration Date
 04/29/2026
Installation Instructions
 FL37207_R1_II_95131.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
37207.4 UDHT- G 2 over UDHP - G 2 2H Combination Assembly Ultimate Double Hung Transom - Generation 2 over Ultimate Double Hung Picture - Generation 2 2H Mull 407-H-1127
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Max Size Mulled Assembly: 1759mm x 2722mm (69 1/4" x 107 3/16") Max Size Picture: 1759mm x 2019mm (69 1/4" x 79 1/2") Glass makeup, IG comprised of two 4.7mm annealed panes separated by a 12.7mm metal spacer. Max Size Transom: 1759mm x 703mm (69 1/4" x 27 11/16") Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL37207_R1_C_CAC_UDHT G2 CCL 1127.22.23.pdf
Quality Assurance Contract Expiration Date
 03/29/2026
Installation Instructions
 FL37207_R1_II_94973.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 