| 37207.1 |
UDH - G2 4032 2W Combination Assembly |
Ultimate Double Hung - Generation 2 mulled to Clad Ultimate Double Hung - Generation 2 2W Combination Assembly 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size of Mulled Assembly: 2299mm x 1816mm (90 1/2" x 71 1/2"), Tributary Width 1149mm Span 1816mm ; Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300. |
Certification Agency Certificate FL37207_R1_C_CAC_UDH G2 CCL 1127.28.29.pdf Quality Assurance Contract Expiration Date 03/29/2026 Installation Instructions FL37207_R1_II_94934.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37207.2 |
UDHT - G2 2W over UDH - G2 2W Vertical Mull (3/8" MRF) 2W2H |
Ultimate Double Hung Transom - Generation 2 2W over Ultimate Double Hung - Generation 2 2W, Vertical Mull (3/8" MRF) 2W2H 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Max Size Mulled Assembly: 2308mm x 2113mm (90 7/8" x 83 3/16") ;Operator & Transom Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300. |
Certification Agency Certificate FL37207_R1_C_CAC_UDHT G2 CCL 1127.26.27.pdf Quality Assurance Contract Expiration Date 04/29/2026 Installation Instructions FL37207_R1_II_95061.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37207.3 |
UDHT - G2 4020 2W over 2W UDH - G2 4020 Vertical Mull (1" LVL) 2W2H |
Ultimate Double Hung Transom - Generation 2 2W over Ultimate Double Hung - Generation 2 2W, Vertical Mull (1" LVL) 2W2H 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size of Mulled Assembly: 2324mm x 1910mm (91 1/2" x 75 3/16") ;1905mm span x 1160mm trib width ( 75" span x 45-3/4" Trib Width); Operator & Transom Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300. |
Certification Agency Certificate FL37207_R1_C_CAC_UDHT G2 CCL 1127.24.25.pdf Quality Assurance Contract Expiration Date 04/29/2026 Installation Instructions FL37207_R1_II_95131.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37207.4 |
UDHT- G 2 over UDHP - G 2 2H Combination Assembly |
Ultimate Double Hung Transom - Generation 2 over Ultimate Double Hung Picture - Generation 2 2H Mull 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size Mulled Assembly: 1759mm x 2722mm (69 1/4" x 107 3/16") Max Size Picture: 1759mm x 2019mm (69 1/4" x 79 1/2") Glass makeup, IG comprised of two 4.7mm annealed panes separated by a 12.7mm metal spacer. Max Size Transom: 1759mm x 703mm (69 1/4" x 27 11/16") Glass makeup, IG comprised of two 3.1mm annealed panes separated by a 16mm metal spacer. Glass complies with ASTM E1300. |
Certification Agency Certificate FL37207_R1_C_CAC_UDHT G2 CCL 1127.22.23.pdf Quality Assurance Contract Expiration Date 03/29/2026 Installation Instructions FL37207_R1_II_94973.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |