| 37202.1 |
UDHG2 4032 2W Mull |
Ultimate Double Hung G2 mulled to Ultimate Double Hung G2 2W Combination Assembly, 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size Mulled Assembly: 2299mm x 1816mm (90 1/2" x 71 1/2"); Tributary Width 1149mm; Span 1816mm; Glass makeup - 3.1mm/16mm/3.1mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHG2 2W Mull CCL 1127.28.29.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_Installation 00094934.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37202.2 |
UDHG2 IZ3 2W Vertical Mull (3/8" MRF) |
Ultimate Double Hung G2 mulled to Ultimate Double Hung G2 2W (3/8" MRF), 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max Size Mulled Assembly: 2308mm x 2019mm (90 7/8" x 79 1/2"); Glass make-up - 23.1mm IG, 3.1mm/0.09"PVB/3.1mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHG2 2W MRF IZ3 Mull CCL 1127.32.39.41.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_99550.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37202.3 |
UDHG2 IZ3 4036 2W Mull |
Ultimate Double Hung G2 IZ3 4036 2W Combination Assembly, 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max Size Mulled Assembly: 2299mm x 1613mm (90 1/2" x 63 1/2"); Glass make-up - 23.1mm IG, 3.1mm/11.5mm/8.6mm made up of 3.1mm/0.09"PVB/3.1mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHG2 2W IZ3 Mull CCL 1127.32.36.37.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_99580.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37202.4 |
UDHTRG2 IZ3 over UDHG2 IZ3 2H Mull |
Ultimate Double Hung Transom G2 IZ3 over Ultimate Double Hung G2 IZ3 2H Combination Assembly, 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Max Size Mulled Assembly: 1251mm x 2722mm (49 1/4" x 107 3/16"); Glass makeup - 23.1mm IG, 3.1mm/11.5mm/8.6mm made up of 3.1mm/0.09"PVB/3.1mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHG2-UDHTRG2 2H IZ3 Mull CCL 1127.32.33.34.38.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_95060.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37202.5 |
UDHTRG2 over UDHG2 2W2H Vertical Mull (3/8" MRF) |
Ultimate Double Hung Transom G2 over Ultimate Double Hung G2 Vertical Mull, 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Max Size Mulled Assembly: 2308mm x 2113mm (90 7/8" x 83 3/16"); Glass make-up - 3.1mm/16mm/3.1mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHTRG2 over UDHG2 2W2H MRF Mull CCL 1127.26.27.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_Installation 00095061.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37202.6 |
UDHTRG2 over UDHG2 4020 2W2H Vertical Mull (1" LVL) |
Ultimate Double Hung Transom G2 over Ultimate Double Hung G2 Vertical Mull, 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size Mulled Assembly: 2324mm x 1910mm (91 1/2" x 75 3/16"); Tributary Width 1160mm; Span 1905mm; Glass make-up - 3.1mm/16mm/3.1mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHTRG2 over UDHG2 2W2H LVL Mull CCL 1127.24.25.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_Installation 00095131.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37202.7 |
UDHTRG2 over UDHPG2 2H Mull |
Ultimate Double Hung Transom G2 over Ultimate Double Hung Picture G2 2H Mull, 407-H-1127 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size Mulled Assembly: 1759mm x 2722mm (69 1/4" x 107 3/16"); Glass make-up - 4.7mm/12.7mm/4.7mm. Glass complies with ASTM E1300 |
Certification Agency Certificate FL37202_R2_C_CAC_UDHTRG2 over UDHPG2 2H Mull CCL 1127.22.23.pdf Quality Assurance Contract Expiration Date 09/27/2029 Installation Instructions FL37202_R2_II_Installation 00094973.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |