9860.1 |
SENTRIGARD ML 200 |
24 Ga. 2" Mechanical Lock 18 7/8" Wide over 22 Ga. Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -54.3 psf @ 36" o.c. Clip Spacing. -153.5 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL9860_R6_II_FL 9860.1 ML 200 24 Ga. over Steel Deck HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.1 ML 200 24 Ga. over Steel Deck HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.2 |
Sentrigard ML 200 AH |
2" Mechanical Lock 0.032" Aluminum 19" Wide over 22 Ga. Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5 Other: -71.0 psf @ 24" o.c. Clip Spacing. -138.5 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones. |
Installation Instructions FL9860_R6_II_FL 9860.2 ML 200AH Alum over Steel Deck HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.2 ML 200AH Alum over Steel Deck HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.3 |
SENTRIGARD ML100 AH |
1.0 Mechnical Lock 0.032" Aluminum 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -63.5 psf @ 24" o.c. Clip Spacing. -101.0 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones.
|
Installation Instructions FL9860_R6_II_FL 9860.3 ML 100AH Alum over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.3 ML 100AH Alum over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.4 |
SENTRIGARD ML100 H |
1.0 Mechanical Lock, 24 Ga. 16 1/2" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -71.0 psf @ 24" o.c. Clip Spacing. -138.5 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details.
For use in HVHZ Zones.
|
Installation Instructions FL9860_R6_II_FL 9860.4 ML 100H 24 Ga. over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.4 ML 100H 24 Ga. over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.5 |
SENTRIGARD ML150 H |
1.5 Mechanical Lock, 24 Ga. Steel, 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -123.5 psf @ 6" o.c. Clip Spacing. -59.75 psf @ 24" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones. |
Installation Instructions FL9860_R6_II_FL 9860.5 ML 150H 24 Ga. over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.5 ML 150H 24 Ga. over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.6 |
SENTRIGARD ML150AH |
1.5 Mechanical Lock 0.032" Aluminum, 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5psf Other: -78.5 psf @ 18" o.c. Clip Spacing. -93.5 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones |
Installation Instructions FL9860_R6_II_FL 9860.6 ML 150AH Aluminum over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.6 ML 150AH Aluminum over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.7 |
SENTRIGARD NS 100 |
1.0 Nail Strip, 24 Ga. Steel, 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5PSF Other: -153.5 psf @ 6-3/4" o.c. Fastener Spacing in slot and 12" o.c. Fastener Spacing in pan. -101.0 psf @ 6-3/4" o.c. Fastener Spacing in pan. -59.75 psf @ 16 o.c. Fastener Spacing in slot. Install per Manufacturer's Details. Not for use in HVHZ Zones. |
Installation Instructions FL9860_R6_II_FL 9860.7 NS 100 24 Ga. over Plywood_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.7 NS 100 24 Ga. over Plywood_sealed.pdf Created by Independent Third Party: Yes |
|
9860.8 |
SENTRIGARD NS150 H |
1.5 Nail Strip , 24 Ga., 15 1/2" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 PSF Other: -116.0 psf @ 6-1/2" o.c. Fastener Spacing in slot and 12" o.c. Fastener Spacing in pan
-78.5 psf @ 11" o.c. Fastener Spacing in slot. Install per Manufacturer's Details. For use in HVHZ Zones. |
Installation Instructions FL9860_R6_II_FL 9860.8 NS 150H 24 Ga. over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.8 NS 150H 24 Ga. over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.9 |
SENTRIGARD SL 175H |
1.75 Snap Lock 17 3/4" Wide over 22 Ga. Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -71.0 psf @ 24" o.c. Clip Spacing. -108.5 psf @ 6" o.c. Clip Spacing.. Install per Manufacturer's Details. For use in HVHZ Zones. |
Installation Instructions FL9860_R6_II_FL 9860.9 SL 175H 24 Ga. over Steel Deck HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.9 SL 175H 24 Ga. over Steel Deck HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
9860.10 |
SENTRIGARD SL100 H |
1.0 Snap Lock, 24 Ga. Steel, 17" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131PSF Other: -67.3 psf @ 24" o.c. Clip Spacing. -131.0 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones.
|
Installation Instructions FL9860_R6_II_FL 9860.10 SL 100H 24 Ga. over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.10 SL 100H 24 Ga. over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
9860.11 |
SENTRIGARD SL150 H |
1.5 Snap Lock, 24 Ga. 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @12" o.c. Clip spacing. -86.0 psf @ 24" o.c. Clip Spacing.
-116.0 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones.
|
Installation Instructions FL9860_R6_II_FL 9860.11 SL 150H 24 Ga. over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9860_R6_AE_FL 9860.11 SL 150H 24 Ga. over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes |