| 25868.1 |
ZIP-RIB |
.032 in. & .040 in. x 12 in. Zip Rib;
.032 in. & .040 in. x 16 in. Zip
Rib;
24 & 22 gage x 12 in. Zip Rib;
24 & 22 gage x 16 in. Zip Rib |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +52.5/-52.5 Other: This compliance is not for HVHZ. 2. Panels to be installed in accordance with UL 580 Construction 216B. 3. Impact resistance is not evaluated. 4. Min. roof slope is 0.50/12. 5. Allowable load capacity of 52.5 psf assumes a factor of safety of 2. 6. Increased design pressures at perimeter and corner areas, in accordance with FBC Chapter 16, may be met by rational analysis. 7. Applies to all material gages 0.032", 0.040" alum. or zinc, 24 ga, 22 ga steel, 0.022" copper. |
Certification Agency Certificate FL25868_R1_C_CAC_UL Construction No 216B.pdf Quality Assurance Contract Expiration Date 02/04/2024 Installation Instructions FL25868_R1_II_UL Construction No 216B.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |