Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL25868-R1
Application Type Revision
Code Version 2020
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Merchant & Evans, Inc
Address/Phone/Email 308 Connecticut Drive
Burlington, NJ 08016
(609) 387-4838
dmcauliffe@ziprib.com
 
Authorized Signature Mike Boland
dmcauliffe@ziprib.com
 
Technical Representative Mike Boland
Address/Phone/Email 308 Connecticut Drive
Burlington, NJ 08016
(609) 387-3033
mboland@ziprib.com
 
Quality Assurance Representative Mike Boland
Address/Phone/Email 308 Connecticut Drive
Burlington, FL 08016
(609) 387-3033
mboland@ziprib.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Certification Mark or Listing
 
Certification Agency UL LLC
Validated By John Southard, P.E.
  Validation Checklist - Hardcopy Received
 
 
Referenced Standard and Year (of Standard)
StandardYear
UL 5802006
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 02/04/2021
Date Validated 02/04/2021
Date Pending FBC Approval
Date Approved 02/12/2021
 
Summary of Products
FL # Model, Number or Name Description
25868.1 ZIP-RIB .032 in. & .040 in. x 12 in. Zip Rib; .032 in. & .040 in. x 16 in. Zip Rib; 24 & 22 gage x 12 in. Zip Rib; 24 & 22 gage x 16 in. Zip Rib
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +52.5/-52.5
 Other: This compliance is not for HVHZ. 2. Panels to be installed in accordance with UL 580 Construction 216B. 3. Impact resistance is not evaluated. 4. Min. roof slope is 0.50/12. 5. Allowable load capacity of 52.5 psf assumes a factor of safety of 2. 6. Increased design pressures at perimeter and corner areas, in accordance with FBC Chapter 16, may be met by rational analysis. 7. Applies to all material gages 0.032", 0.040" alum. or zinc, 24 ga, 22 ga steel, 0.022" copper.
Certification Agency Certificate
 FL25868_R1_C_CAC_UL Construction No 216B.pdf
Quality Assurance Contract Expiration Date
 02/04/2024
Installation Instructions
 FL25868_R1_II_UL Construction No 216B.pdf
 Verified By: UL LLC
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 