| 47673.1 |
SP Aluminum Clad Casement |
SP Aluminum Clad Casement 60x96 (30x96-2) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL47673_R1_C_CAC_Sierra429-565.10-.14CCL (1).pdf Quality Assurance Contract Expiration Date 09/24/2034 Installation Instructions FL47673_R1_II_Clad Sierra Pacific Casement Twin 60x96 CCL429-H-565_10-14 S2881.01-901-47-RO.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47673.2 |
SP Aluminum Clad Casement 48x96 |
SP Alum Clad Casement Oper 48x96-NF |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL47673_R1_C_CAC_Sierra429-565.00-.04CCL (1).pdf Quality Assurance Contract Expiration Date 09/25/2034 Installation Instructions FL47673_R1_II_Clad Sierra Pacific Casement 48x96 CCL429-H-565_00-04 S3069.01-901-47-RO.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47673.3 |
SP Aluminum Clad Casement 48x96 |
SP Alum Clad Casement 48x96-Thru Frame |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL47673_R1_C_CAC_Sierra429-565.05-.09CCL (1).pdf Quality Assurance Contract Expiration Date 01/16/2035 Installation Instructions FL47673_R1_II_Clad Sierra Pacific Casement 48x96 CCL429-H-565_05-09 S4378.01-901-47-R1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47673.4 |
SP Aluminum Clad Casement 72x84 |
SP Aluminum Clad Casement 72x84(36x72-2) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL47673_R1_C_CAC_Sierra429-565.15-.18 CCL.pdf Quality Assurance Contract Expiration Date 09/24/2034 Installation Instructions FL47673_R1_II_Clad Sierra Pacific Casement Twin 72x84 CCL429-H-565_15-18 S3072.01-901-47-R0.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47673.5 |
SP Aluminum Clad Casement/Awning/Fix Combo 108x104-1/4" |
SP Aluminum Clad CSE/AWN/FIX Combo 108"x104-1/4 (36x75-3/36x72-3) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL47673_R1_C_CAC_Sierra429-565.19-.22CCL (1).pdf Quality Assurance Contract Expiration Date 09/26/2034 Installation Instructions FL47673_R1_II_Clad Sierra Pacific Csmt-Awn Combo 108x104.25 CCL429-H-565_19-22 S3266.01-901-47-R0.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |