| 4574.1 |
Super Pro |
26 Ga. Super Pro over 1 x 4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -76.8 psf at 9"-9"-9"-9" at 24" o.c. -108.5 psf at 9"-9"-9"-9" at 12" o.c. fastener spacing. |
Installation Instructions FL4574_R7_II_26ga_SuperPro_1x4.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL4574_R7_AE_26ga_SuperPro_1x4.pdf Created by Independent Third Party: Yes |
|
|
| 4574.2 |
Super Pro |
29 Ga. Super Pro over 1 x 4 Wood Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -74.3 at 9"-9"-9"-9" at 24" o.c. -108.5 psf at 9"-9"-9"-9" at 12" o.c. fastener spacing. |
Installation Instructions FL4574_R7_II_29ga_SuperPro_1x4.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL4574_R7_AE_29ga_SuperPro_1x4.pdf Created by Independent Third Party: Yes |
|
|
| 4574.3 |
Super Pro PBR |
26 Ga. Super Pro PBR Roof Panel over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +165/-111.85 Other: -36.4 psf and +46.9 psf at 12"-12"-12" at 5' o.c. | -111.85 psf and +165.0 psf at 12"-12"-12" at 2' o.c. |
Installation Instructions FL4574_R7_II_26ga_SuperPro_PBR_16gaSteel.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL4574_R7_AE_26ga_SuperPro_PBR_16gaSteel.pdf Created by Independent Third Party: Yes |