| 6282.1 |
"A"/"PBA - Panel" |
Wall Panel, 26 and 24 Gauge Steel, 36" Wide Panel, Attached to Structural Supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26/-26 Other: + 26 / -26 psf allowable load based on 26 gauge panel on supports at 5'-0" o.c. Refer to Evaluation Report for additional Span Load values. |
Installation Instructions FL6282_R9_II_FL6282.1 Installation.pdf Verified By: T. James Eisenman, JR 61944 Created by Independent Third Party: No Evaluation Reports FL6282_R9_AE_FL6282.1 (2026).pdf Created by Independent Third Party: Yes |
|
|
| 6282.2 |
1- "R"/"PBR"-Panel |
Wall Panel, 24 Gauge Steel, 50 ksi, 36" Wide Panel, Attached to Structural Supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +47/-41 Other: + 47 / - 41 psf allowable load based on supports at 5'-0" o.c. Refer to Evaluation Report for additional Span Load values. |
Installation Instructions FL6282_R9_II_R - PBR Wall Installation Instructions.pdf Verified By: T. James Eisenman, Jr. 61944 Created by Independent Third Party: No Evaluation Reports FL6282_R9_AE_FL6282.2 (2026).pdf Created by Independent Third Party: Yes |
|
|
| 6282.3 |
2- "R"/"PBR"-Panel |
Wall Panel, 24 Gauge Steel, 80 ksi, 36" Wide Panel, Attached to Structural Supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +54/-41 Other: + 54 / -41 psf allowable load based on supports at 5'-0" o.c. Refer to Evaluation Report for additional Span Load values. |
Installation Instructions FL6282_R9_II_R - PBR Wall Installation Instructions.pdf Verified By: T. James Eisenman, Jr. 61944 Created by Independent Third Party: No Evaluation Reports FL6282_R9_AE_FL6282.3 (2026).pdf Created by Independent Third Party: Yes |
|
|
| 6282.4 |
3- "R"/"PBR"-Panel |
Wall Panel, 26 Gauge Steel, 36" Wide Panel, Attached to Structural Supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +41/-41 Other: + 41 / -41 psf allowable load based on supports at 5'-0" o.c. Refer to Evaluation Report for additional Span Load values. |
Installation Instructions FL6282_R9_II_R - PBR Wall Installation Instructions.pdf Verified By: T. James Eisenman, Jr. 619444 Created by Independent Third Party: No Evaluation Reports FL6282_R9_AE_FL6282.4 (2026).pdf Created by Independent Third Party: Yes |