| 19063.1 |
ES-P250 Aluminum Thermally Broken Fixed Window |
Non-impact resistant thermal aluminum fixed window. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: See drawing W15-78 for span vs load combinations and installation details. |
Installation Instructions FL19063_R4_II_SS - ES- P250 FIXED (NI)-DWG W15-78 2026.pdf FL19063_R4_II_zSS - Coastal Anchors Statement of Equivalency.pdf Verified By: Jalal Farooq PE #81223 Created by Independent Third Party: Yes Evaluation Reports FL19063_R4_AE_SS - ES- P250 FIXED (NI)-PAE 2026.pdf Created by Independent Third Party: Yes |