| 8071.1 |
4000 series |
4000 series open back commercial steel sectional garage doors, maximum 9'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.5/-33.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO9A_24.5_33.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.2 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 9'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33.0/-37.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO9A_33.0_37.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.3 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 10'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.0/-28.5 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO10A_25.0_28.5_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.4 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 10'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33.0/-37.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO10A_33.0_37.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.5 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 12'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +23.0/-23.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO12A_23.0_23.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.6 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 12'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28.0/-31.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO12A_28.0_31.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.7 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 12'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33.0/-36.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO12A_33.0_36.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.8 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 16'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.5/-35.5 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO16A_31.5_35.5_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.9 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 14'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20.6/-22.9 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO14A_20.6_22.9_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.10 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 14'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.3/-26.5 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO14A_24.3_26.5_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.11 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 16'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +18.7/-20.4 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO16A_18.7_20.4_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.12 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 18'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.9/-28.1 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO18A_24.9_28.1_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.13 |
4000 series |
4000 series open back commercial steel sectional garage door, maximum 20'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20.2/-22.8 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. Optional polystyrene insulation is available. |
Installation Instructions FL8071_R7_II_CO20A_20.2_22.8_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.14 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 14'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20.6/-22.9 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS14A_20.6_22.9_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.15 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 14'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.3/-26.5 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS14A_24.3_26.5_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.16 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 16'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +18.7/-20.4 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS16A_18.7_20.4_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.17 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 18'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +21.4/-23.8 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS18A_21.4_23.8_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.18 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 20'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +17.3/-19.3 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS20A_17.3_19.3_REV01_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.19 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 9'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33.0/-37.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS9A_33.0_37.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |
|
|
| 8071.20 |
6500 series |
6500 series sandwich panel commercial steel sectional garage doors, maximum 10'2" width |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28.0/-32.0 Other: Doors with glazing shall not be used in the wind-borne debris region. Maximum door height is 24'. |
Installation Instructions FL8071_R7_II_CS10A_28.0_32.0_REV02_s.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL8071_R7_AE_EvalRept 8071_s.pdf Created by Independent Third Party: Yes |